Sequential injection monosegmented flow voltammetric determination of cadmium and lead using a bismuth film working electrode.

Watsaka Siriangkhawut1, Somkid Pencharee, Kate Grudpan, Jaroon Jakmunee.   

Abstract

A cost-effective sequential injection monosegmented flow analysis (SI-MSFA) with anodic stripping voltammetric (ASV) detection has been developed for determination of Cd(II) and Pb(II). The bismuth film working electrode (BiFE) was employed for accumulative preconcentration of the metals by applying a fixed potential of -1.10 V versus Ag/AgCl electrode for 90 s. The SI-MSFA provides a convenient means for preparation of a homogeneous solution zone containing sample in an acetate buffer electrolyte solution and Bi(III) solution for in situ plating of BiFE, ready for ASV measurement at a flow through thin layer electrochemical cell. Under the optimum conditions, linear calibration graphs in range of 10-100 microg L(-1) of both Cd(II) and Pb(II) were obtained with detection limits of 1.4 and 6.9 microg L(-1) of Cd(II) and Pb(II), respectively. Relative standard deviations were 2.7 and 3.1%, for 11 replicate analyses of 25 microg L(-1) Cd(II) and 25 microg L(-1) Pb(II), respectively. A sample throughput of 12h(-1) was achieved with low consumption of reagent and sample solutions. The system was successfully applied for analysis of water samples collected from a draining pond of zinc mining, validating by inductively coupled plasma-optical emission spectroscopy (ICP-OES) method.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19615519     DOI: 10.1016/j.talanta.2009.03.032

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrode.

Authors:  Kristie C Armstrong; Clarissa E Tatum; Royce N Dansby-Sparks; James Q Chambers; Zi-Ling Xue
Journal:  Talanta       Date:  2010-05-20       Impact factor: 6.057

2.  Metallo-graphene nanocomposite electrocatalytic platform for the determination of toxic metal ions.

Authors:  Chandre M Willemse; Khotso Tlhomelang; Nazeem Jahed; Priscilla G Baker; Emmanuel I Iwuoha
Journal:  Sensors (Basel)       Date:  2011-04-01       Impact factor: 3.576

Review 3.  Recent Advances in the Fabrication and Application of Screen-Printed Electrochemical (Bio)Sensors Based on Carbon Materials for Biomedical, Agri-Food and Environmental Analyses.

Authors:  Gareth Hughes; Kelly Westmacott; Kevin C Honeychurch; Adrian Crew; Roy M Pemberton; John P Hart
Journal:  Biosensors (Basel)       Date:  2016-09-28

4.  Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample.

Authors:  Sam-Ang Supharoek; Kraingkrai Ponhong; Watsaka Siriangkhawut; Kate Grudpan
Journal:  J Food Drug Anal       Date:  2017-07-08       Impact factor: 6.157