Literature DB >> 19615509

Separation/preconcentration and determination of cadmium ions by solidification of floating organic drop microextraction and FI-AAS.

Shayessteh Dadfarnia1, Ali Mohammad Haji Shabani, Elahe Kamranzadeh.   

Abstract

A simple and selective method for the separation and preconcentration of cadmium in water samples based on solidified floating organic drop microextraction (SFODME) was developed. The cadmium ion in aqueous solution was converted to CdI(4)(2-) and was then extracted with 160 microL of 1-undecanol containing cationic surfactant of methyltrioctylammonium chloride (0.2 mol/L). When the extraction was completed, the sample vial was cooled in an ice bath for 5 min. The solidified extract was transferred into a conical vial where it melted immediately. It was then diluted to 250 microL upon addition of ethanol, and 100 microL of it was analyzed by flow injection flame atomic absorption spectrometry (FI-FAAS). Factors that influence the extraction and ion pair formation, such as pH, concentration of iodide and methyltrioctylammonium chloride, extraction time, sample volume, and ionic strength were optimized. Under the optimized conditions, a preconcentration factor of 640, detection limit of 0.0079 microg/L and good relative standard deviation of +/-5.4% at 5 microg/L were obtained. The procedure was applied to tap water, well water, and sea water; and accuracy was assessed through recovery experiment and independent analysis by graphite atomic absorption spectrometry. The accuracy was also evaluated through analyses of certified reference ore.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19615509     DOI: 10.1016/j.talanta.2009.02.004

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Separation/preconcentration and determination of quercetin in food samples by dispersive liquid-liquid microextraction based on solidification of floating organic drop -flow injection spectrophotometry.

Authors:  Tahereh Asadollahi; Shayessteh Dadfarnia; Ali Mohammad Haji Shabani; Mooud Amirkavei
Journal:  J Food Sci Technol       Date:  2013-07-09       Impact factor: 2.701

2.  Methods of liquid phase microextraction for the determination of cadmium in environmental samples.

Authors:  Analú Pires Santos; Maria das Graças Andrade Korn; Valfredo Azevedo Lemos
Journal:  Environ Monit Assess       Date:  2017-08-09       Impact factor: 2.513

Review 3.  Metal Cation Detection in Drinking Water.

Authors:  Johnson Dalmieda; Peter Kruse
Journal:  Sensors (Basel)       Date:  2019-11-23       Impact factor: 3.576

4.  Pseudo-stir bar hollow fiber solid/liquid phase microextraction combined with anodic stripping voltammetry for determination of lead and cadmium in water samples.

Authors:  Zarrin Es'haghi; Hasan Ali Hoseini; Saeed Mohammadi-Nokhandani; Javad Ebrahimi
Journal:  J Adv Res       Date:  2013-11-20       Impact factor: 10.479

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.