Literature DB >> 19615507

Determination of traces of palladium in stream sediment and auto catalyst by FI-ICP-OES using on-line separation and preconcentration with QuadraSil TA.

Junichi Nakajima1, Masashi Ohno, Katsumi Chikama, Tatsuya Seki, Koichi Oguma.   

Abstract

A flow injection analysis (FIA) method using on-line separation and preconcentration with a novel metal scavenger beads, QuadraSil TA, has been developed for the ICP-OES determination of traces of palladium. QuadraSil TA contains diethylenetriamine as a functional group on spherical silica beads and shows the highest selectivity for Pd(II) at pH 1 (0.1 mol l(-1) hydrochloric acid) solution. An aliquot of the sample solution prepared as 0.1 mol l(-1) in hydrochloric acid was passed through the QuadraSil TA column. After washing the column with the carrier solution, the Pd(II) retained on the column was eluted with 0.05 mol l(-1) thiourea solution and the eluate was directly introduced into an ICP-OES. The proposed method was successfully applied to the determination of traces of palladium in JSd-2 stream sediment certified reference material [0.019+/-0.001 microg g(-1) (n=3); provisional value: 0.0212 microg g(-1)] and SRM 2556 used auto catalyst certified reference material [315+/-4 microg g(-1) (n=4); certified value: 326 microg g(-1)]. The detection limit (3 sigma) of 0.28 ng ml(-1) was obtained for 5 ml of sample solution. The sample through puts for 5 ml and 100 microl of the sample solutions were 10 and 15 h(-1), respectively.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19615507     DOI: 10.1016/j.talanta.2009.02.035

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Application of nanoclay for preconcentration of ultra trace amounts of palladium in environmental samples prior to its determination by ETAAS.

Authors:  Mohammad Ali Taher; Nezhat Jandaghi; Hamid Fazelirad; Hamid Ashkenani
Journal:  Environ Monit Assess       Date:  2014-03       Impact factor: 2.513

2.  An accurate and sensitive analytical strategy for the determination of palladium in aqueous samples: slotted quartz tube flame atomic absorption spectrometry with switchable liquid-liquid microextraction after preconcentration using a Schiff base ligand.

Authors:  Merve Fırat; Emine Gülhan Bakırdere
Journal:  Environ Monit Assess       Date:  2019-02-05       Impact factor: 2.513

3.  Tropaeolin OO as a Chemical Sensor for a Trace Amount of Pd(II) Ions Determination.

Authors:  Adrianna Pach; Agnieszka Podborska; Edit Csapo; Magdalena Luty-Błocho
Journal:  Molecules       Date:  2022-07-14       Impact factor: 4.927

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.