Literature DB >> 19614788

Void detection in root fillings using intraoral analogue, intraoral digital and cone beam CT images.

B Huybrechts1, M Bud, L Bergmans, P Lambrechts, R Jacobs.   

Abstract

AIM: To compare void detection in root fillings using different radiographic imaging techniques: intraoral analogue, intraoral digital and cone beam CT (CBCT) images and to assess factors influencing small void detection.
METHODOLOGY: Two straight root canals in canine teeth were prepared. Calibrated steel wires of five different diameters (200, 300, 350, 500, 800 microm) were inserted respectively in the canal after the injection of a sealer. To simulate filling voids of known dimensions, the wires were removed after the sealer had set. Each sample was imaged, using a Minray X-ray tube (Soredex, Helsinki, Finland) at optimal clinical settings combined with Vistascan PSP (Dürr Dental, Bietigheim-Bissingen, Germany), Digora Optime PSP (Soredex), Sigma CCD (Instrumentarium, Tuusula, Finland) and E-speed films (Agfa-Gevaert, Mortsel, Belgium). The teeth were also imaged using CBCT (3D Accuitomo, Morita, Japan). A generalized mixed model and ANOVA analysis were used on the acquired data (Tukey-Kramer correction).
RESULTS: There was no evidence that the factor 'root level' affected void detection in root fillings. 'Void size' was a main determining factor as all voids larger than 300 microm were determined with all techniques. For the smaller voids, there were significant differences between the 5 imaging techniques at different void sizes and different root levels.
CONCLUSIONS: Void size and imaging technique were main determining factors. Voids larger than 300 mum were determined with all imaging techniques. For small void detection, all digital intraoral techniques performed better than intraoral analogue and CBCT images.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19614788     DOI: 10.1111/j.1365-2591.2009.01566.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  18 in total

1.  Influence of apical taper on the quality of thermoplasticized root fillings assessed by micro-computed tomography.

Authors:  C Zogheib; A Naaman; E Medioni; R Arbab-Chirani
Journal:  Clin Oral Investig       Date:  2011-11-25       Impact factor: 3.573

Review 2.  [Comparison between cone beam computed tomography and periapical radiography in the diagnosis of periapical disease].

Authors:  Gao Jing; Shen Jing
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2015-04

3.  Comparing cone-beam computed tomography with periapical radiography for assessing root canal obturation in vivo using microsurgical findings as validation.

Authors:  Dongzhe Song; Lan Zhang; Wei Zhou; Qinghua Zheng; Xingyu Duan; Xuedong Zhou; Dingming Huang
Journal:  Dentomaxillofac Radiol       Date:  2017-03-23       Impact factor: 2.419

4.  Comparative micro-computed tomographic evaluation of two carrier-based obturation systems.

Authors:  Carla Zogheib; A Naaman; A Sigurdsson; E Medioni; G Bourbouze; R Arbab-Chirani
Journal:  Clin Oral Investig       Date:  2012-11-01       Impact factor: 3.573

5.  Clinical Assessment of Various Obturating Techniques for Primary Teeth: A Comparative Study.

Authors:  Mahima Gandhi; Sandeep Tandon; Akshat Vijay; Garima Kalia; Khushboo Rathore
Journal:  J Clin Diagn Res       Date:  2017-07-01

6.  Technical quality of a matching-taper single-cone filling technique following rotary instrumentation compared with lateral compaction after manual preparation: a retrospective study.

Authors:  R Krug; G Krastl; M Jahreis
Journal:  Clin Oral Investig       Date:  2016-08-13       Impact factor: 3.573

7.  Conventional versus digital radiographs in detecting artificial voids in root canal filling material.

Authors:  Mohammad Mahdi Aghdasi; Mohammad Asnaashari; Alireza Aliari; Farahnaz Fahimipour; Sepideh Soheilifar
Journal:  Iran Endod J       Date:  2011-08-15

8.  The association between complete absence of post-treatment periapical lesion and quality of root canal filling.

Authors:  Yu-Hong Liang; Gang Li; Hagay Shemesh; Paul R Wesselink; Min-Kai Wu
Journal:  Clin Oral Investig       Date:  2012-01-10       Impact factor: 3.573

9.  Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars.

Authors:  Clarissa Teles Rodrigues; Reinhilde Jacobs; Karla Faria Vasconcelos; Paul Lambrechts; Izabel Regina Fisher Rubira-Bullen; Hugo Gaêta-Araujo; Christiano Oliveira-Santos; Marco Antonio Hungaro Duarte
Journal:  Dentomaxillofac Radiol       Date:  2021-01-05       Impact factor: 3.525

10.  Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques.

Authors:  Kemal Özgür Demiralp; Kıvanç Kamburoğlu; Kahraman Güngör; Selcen Yüksel; Gokcen Demiralp; Ozlem Uçok
Journal:  Imaging Sci Dent       Date:  2012-09-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.