Literature DB >> 19610322

Development and evaluation of an efficient approach to volumetric arc therapy planning.

Karl Bzdusek1, Henrik Friberger, Kjell Eriksson, Björn Hårdemark, David Robinson, Michael Kaus.   

Abstract

An efficient method for volumetric intensity modulated arc therapy (VMAT) planning was developed, where a single arc (360 degrees or less) is delivered under continuous variation of multileaf collimator (MLC) segments, dose rate, and gantry speed. Plans can be generated for any current linear accelerator that supports these degrees of freedom. MLC segments are derived from fluence maps at relatively coarsely sampled angular positions. The beam segments, dose rate, and gantry speed are then optimized using direct machine parameter optimization based on dose volume objectives and leaf motion constraints to minimize arc delivery time. The method can vary both dose rate and gantry speed or alternatively determine the optimal plan at constant dose rate and gantry speed. The method was used to retrospectively generate variable dose rate VMAT plans to ten patients (head and neck, prostate, brain, lung, and tonsil). In comparison to step-and-shoot intensity modulated radiation therapy, dosimetric plan quality was comparable or improved, estimated delivery times ranged from 70 to 160 s, and monitor units were consistently reduced in nine out of the ten cases by an average of approximately 6%. Optimization and final dose calculation took between 5 and 35 min depending on plan complexity.

Entities:  

Mesh:

Year:  2009        PMID: 19610322     DOI: 10.1118/1.3132234

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  78 in total

1.  Comparative analysis of SmartArc-based dual arc volumetric-modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma.

Authors:  Tsair-Fwu Lee; Pei-Ju Chao; Hui-Min Ting; Su-Hua Lo; Yu-Wen Wang; Chiu-Ching Tuan; Fu-Min Fang; Te-Jen Su
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

2.  Effect of photon-beam energy on VMAT and IMRT treatment plan quality and dosimetric accuracy for advanced prostate cancer.

Authors:  Marlies Pasler; Dietmar Georg; Holger Wirtz; Johannes Lutterbach
Journal:  Strahlenther Onkol       Date:  2011-11-29       Impact factor: 3.621

3.  Multicriteria VMAT optimization.

Authors:  David Craft; Dualta McQuaid; Jeremiah Wala; Wei Chen; Ehsan Salari; Thomas Bortfeld
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

4.  VMAT to arclet plan conversion in a treatment planning system : Feasibility and dosimetric relationship between VMAT, arclet, and stationary fields.

Authors:  Yvonne Dzierma; Norbert Licht; Ian Norton; Frank Nuesken; Christian Rübe; Jochen Fleckenstein
Journal:  Strahlenther Onkol       Date:  2015-09-07       Impact factor: 3.621

5.  Exploring trade-offs between VMAT dose quality and delivery efficiency using a network optimization approach.

Authors:  Ehsan Salari; Jeremiah Wala; David Craft
Journal:  Phys Med Biol       Date:  2012-08-14       Impact factor: 3.609

6.  Single-arc volumetric-modulated arc therapy can provide dose distributions equivalent to fixed-beam intensity-modulated radiation therapy for prostatic irradiation with seminal vesicle and/or lymph node involvement.

Authors:  J D Fontenot; M L King; S A Johnson; C G Wood; M J Price; K K Lo
Journal:  Br J Radiol       Date:  2011-06-28       Impact factor: 3.039

7.  SmartArc-based volumetric modulated arc therapy can improve the middle ear, vestibule and cochlea sparing for locoregionally advanced nasopharyngeal carcinoma: a dosimetric comparison with step-and-shoot intensity-modulated radiotherapy.

Authors:  J Gao; T-L Qian; C-Z Tao; Y-H Zhang; Y Zhou; J Yang; J He; R Wang; P-J Zhou
Journal:  Br J Radiol       Date:  2015-06-25       Impact factor: 3.039

8.  Optimization approaches to volumetric modulated arc therapy planning.

Authors:  Jan Unkelbach; Thomas Bortfeld; David Craft; Markus Alber; Mark Bangert; Rasmus Bokrantz; Danny Chen; Ruijiang Li; Lei Xing; Chunhua Men; Simeon Nill; Dávid Papp; Edwin Romeijn; Ehsan Salari
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

9.  Application of volumetric modulated arc therapy (VMAT) in a dual-vendor environment.

Authors:  Barbara Dobler; Karin Weidner; Oliver Koelbl
Journal:  Radiat Oncol       Date:  2010-10-25       Impact factor: 3.481

10.  Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer.

Authors:  Judith Alvarez-Moret; Fabian Pohl; Oliver Koelbl; Barbara Dobler
Journal:  Radiat Oncol       Date:  2010-11-22       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.