Literature DB >> 19606294

A portable cell-based impedance sensor for toxicity testing of drinking water.

Theresa M Curtis1, Mark W Widder, Linda M Brennan, Steven J Schwager, William H van der Schalie, Julien Fey, Noe Salazar.   

Abstract

A major limitation to using mammalian cell-based biosensors for field testing of drinking water samples is the difficulty of maintaining cell viability and sterility without an on-site cell culture facility. This paper describes a portable automated bench-top mammalian cell-based toxicity sensor that incorporates enclosed fluidic biochips containing endothelial cells monitored by Electric Cell-substrate Impedance Sensing (ECIS) technology. Long-term maintenance of cells on the biochips is made possible by using a compact, self-contained disposable media delivery system. The toxicity sensor monitors changes in impedance of cell monolayers on the biochips after the introduction of water samples. The fluidic biochip includes an ECIS electronic layer and a polycarbonate channel layer, which together reduce initial impedance disturbances seen in commercially available open well ECIS chips caused by the mechanics of pipetting while maintaining the ability of the cells to respond to toxicants. A curve discrimination program was developed that compares impedance values over time between the control and treatment channels on the fluidic biochip and determines if they are significantly different. Toxicant responses of bovine pulmonary artery endothelial cells grown on fluidic biochips are similar to cells on commercially-available open well chips, and these cells can be maintained in the toxicity sensor device for at least nine days using an automated media delivery system. Longer-term cell storage is possible; bovine lung microvessel endothelial cells survive for up to four months on the fluidic biochips and remain responsive to a model toxicant. This is the first demonstration of a portable bench top system capable of both supporting cell health over extended periods of time and obtaining impedance measurements from endothelial cell monolayers after toxicant exposure.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19606294     DOI: 10.1039/b901314h

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  16 in total

1.  Cell suspension concentration monitoring by using a miniaturized serial high frequency SAWR sensor.

Authors:  Jian Li; Hailin Feng; Yiming Fang
Journal:  Bioengineered       Date:  2015       Impact factor: 3.269

Review 2.  Strategies for improving the physiological relevance of human engineered tissues.

Authors:  Rosalyn D Abbott; David L Kaplan
Journal:  Trends Biotechnol       Date:  2015-04-30       Impact factor: 19.536

3.  Enzyme-coated microelectrodes to monitor lactate production in a nanoliter microfluidic cell culture device.

Authors:  Igor A Ges; Franz Baudenbacher
Journal:  Biosens Bioelectron       Date:  2010-06-02       Impact factor: 10.618

4.  Response characteristics of single-cell impedance sensors employed with surface-modified microelectrodes.

Authors:  Myo Thein; Fareid Asphahani; An Cheng; Ryan Buckmaster; Miqin Zhang; Jian Xu
Journal:  Biosens Bioelectron       Date:  2010-01-25       Impact factor: 10.618

5.  Site-specific sonoporation of human melanoma cells at the cellular level using high lateral-resolution ultrasonic micro-transducer arrays.

Authors:  Myo Thein; An Cheng; Payal Khanna; Chunfeng Zhang; Eun-Joo Park; Daniel Ahmed; Christopher J Goodrich; Fareid Asphahani; Fengbing Wu; Nadine B Smith; Cheng Dong; Xiaoning Jiang; Miqin Zhang; Jian Xu
Journal:  Biosens Bioelectron       Date:  2011-06-21       Impact factor: 10.618

6.  Single-cell bioelectrical impedance platform for monitoring cellular response to drug treatment.

Authors:  Fareid Asphahani; Kui Wang; Myo Thein; Omid Veiseh; Sandy Yung; Jian Xu; Miqin Zhang
Journal:  Phys Biol       Date:  2011-02-07       Impact factor: 2.583

7.  Cell-based sensor system using L6 cells for broad band continuous pollutant monitoring in aquatic environments.

Authors:  Rebekka Kubisch; Ulrich Bohrn; Maximilian Fleischer; Evamaria Stütz
Journal:  Sensors (Basel)       Date:  2012-03-08       Impact factor: 3.576

8.  Rapid development of new protein biosensors utilizing peptides obtained via phage display.

Authors:  Jun Wu; Jong Pil Park; Kevin Dooley; Donald M Cropek; Alan C West; Scott Banta
Journal:  PLoS One       Date:  2011-10-07       Impact factor: 3.240

Review 9.  Smart Cell Culture Systems: Integration of Sensors and Actuators into Microphysiological Systems.

Authors:  Mario M Modena; Ketki Chawla; Patrick M Misun; Andreas Hierlemann
Journal:  ACS Chem Biol       Date:  2018-02-15       Impact factor: 5.100

10.  Transient Intervals of Hyper-Gravity Enhance Endothelial Barrier Integrity: Impact of Mechanical and Gravitational Forces Measured Electrically.

Authors:  Robert Szulcek; Jan van Bezu; Johannes Boonstra; Jack J W A van Loon; Geerten P van Nieuw Amerongen
Journal:  PLoS One       Date:  2015-12-04       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.