Literature DB >> 19603618

Combined corneal topography and corneal wavefront data in the treatment of corneal irregularity and refractive error in LASIK or PRK using the Carl Zeiss Meditec MEL 80 and CRS-Master.

Dan Z Reinstein1, Timothy J Archer, Marine Gobbe.   

Abstract

PURPOSE: To assess the efficacy, safety, and accuracy of TOSCA II (Topography Supported Custom Ablation) treatments for the correction of high corneal aberrations and refractive error following previous ocular surgery.
METHODS: Forty-eight eyes of 32 patients were included for study. Indications for TOSCA II treatment included small optical zone, decentered ablation, subjective visually significant higher order aberrations, and irregularly irregular astigmatism induced by LASIK, photorefractive keratectomy, radial keratotomy, conductive keratoplasty, cataract surgery, and deep lamellar keratoplasty. An ablation profile based on corneal topography data and corneal wavefront and manifest refraction was created using the CRS-Master software (Carl Zeiss Meditec) to treat corneal irregularity and refractive error simultaneously. Postoperative assessments were performed at 1 week and 1, 2, 3, 6, and 12 months.
RESULTS: Mean attempted spherical equivalent refraction (SE) was -1.12 +/- 1.97 diopters (D) (range: +1.13 to -10.50 D). Mean attempted cylinder correction was 1.34 +/- 1.65 D (range: 0.00 to 7.75 D). Median age was 38 years (range: 19 to 68 years). Median follow-up was 9.4 months. Accuracy: mean deviation from the intended SE correction was -0.19 +/- 0.94 D, 60% of eyes were within +/- 0.50 D and 77% of eyes were within +/- 1.00 D of the intended SE. Cylinder: the correction ratio was 1.49 +/- 0.85 and the error ratio was 0.87 +/- 0.69. EFFICACY: 56% of eyes achieved uncorrected visual acuity of 20/20 or better and 88% achieved 20/40 or better. SAFETY: 34% of eyes gained one or more lines of best spectacle-corrected visual acuity, 15% lost one line, and no eye lost two or more lines. Contrast sensitivity: for the subset of eyes with below normal contrast sensitivity preoperatively, there was a statistically significant improvement in contrast sensitivity at 3 cycles per degree (cpd), 6 cpd, and 12 cpd (P < .05). Stability: the average change in refraction between 3 months and 1year was +0.38 +/- 0.30 D. Higher order aberrations: the average higher order root-mean-square decreased by 21% and the average spherical aberration decreased by 41%.
CONCLUSIONS: The MEL 80 CRS-Master TOSCA II software appears to be an effective treatment for decentrations, optical zone enlargement, and reduction of higher order aberrations. The refractive outcome was satisfactory after one treatment.

Entities:  

Mesh:

Year:  2009        PMID: 19603618     DOI: 10.3928/1081597X-20090512-04

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  5 in total

1.  Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-11-16       Impact factor: 3.573

2.  Comparison of clinical outcomes in PRK with a standard and aspherical optimized profile: a full case analysis of 100 eyes with 1-year follow-up.

Authors:  Dieter Dausch; Burglinde Dausch; Matthias Wottke; Georg Sluyterman van Langeweyde
Journal:  Clin Ophthalmol       Date:  2014-11-24

Review 3.  Refractive lenticule extraction small incision lenticule extraction: A new refractive surgery paradigm.

Authors:  Sri Ganesh; Sheetal Brar; Raghavender Reddy Arra
Journal:  Indian J Ophthalmol       Date:  2018-01       Impact factor: 1.848

4.  Contralateral Eye Study of Topography Guided versus Q Value Adjusted Photorefractive Keratectomy in Myopia and Myopic Astigmatism.

Authors:  Rania E Gad; Mohamed Hosny; Rania A Ahmed; Ahmed M Sherif; Yehia Salah Eldin
Journal:  Clin Ophthalmol       Date:  2021-04-23

Review 5.  Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomes.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe
Journal:  Eye Vis (Lond)       Date:  2014-10-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.