Improved esophageal patency when inserting the ProSeal laryngeal mask airway with an Eschmann tracheal tube introducer.

Hossam El Beheiry1, Jean Wong, Gopakumar Nair, Vinod Chinnappa, Gagan Arora, Eduardo Morales, Frances Chung.   

Abstract

PURPOSE: We hypothesized that a more accurate alignment of the tip of the drain tube with the upper esophageal opening would be achieved in adult patients, as confirmed by fibreoptic bronchoscopy, by placing the ProSeal laryngeal mask airway (PLMA) by means of guiding it over an Eschmann tracheal tube introducer, commonly know as a gum elastic bougie (GEB), that was previously inserted into the esophagus, rather than by placing the PLMA with a curved metal introducer (IT).
METHODS: Seventy-five adult elective surgery patients, whose airway management involved a PLMA, were randomly allocated to either the GEB- or IT-guided techniques. After inserting the PLMA, alignment of the tip of the drain tube relative to the esophageal opening was verified by a fibrescope introduced through the drain tube. Placing the fibrescope through the PLMA identified the glottic structures. The primary endpoint indicating the proper alignment of the tip of the drain tube of the PLMA with the upper esophageal opening was the ability to pass the fibrescope into the esophagus through the drain tube by a distance >35 cm without obstruction and the ability to simultaneously visualize the esophageal mucosa.
RESULTS: The overall success rates of PLMA insertion were similar in the GEB and IT groups. However, the mean airway insertion times were longer with the GEB than with the IT-PLMA. The GEB group achieved proper alignment of the drain tube and the upper esophageal opening more frequently than the IT group (97% confidence interval (CI(95)) 91.5-100% vs 81% CI(95) 68.5-93.5% of subjects, respectively; P = 0.027). When the GEB was used to place the PLMA, the patients' vocal cords were visualized more frequently than when the IT technique was used (100% vs 73% CI(95) 58.9-87.1% of subjects, respectively; P = 0.003).
CONCLUSION: Fibreoptic bronchoscopy confirmed that GEB is superior to the IT technique in ensuring precise alignment of the tip of the drain tube of the PLMA with the upper esophageal opening. Accurate positioning may better preserve gastroesophageal drainage function of the PLMA.

Entities:  

Mesh:

Year:  2009        PMID: 19603240     DOI: 10.1007/s12630-009-9141-7

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  3 in total

1.  Validation of the unassisted, gum-elastic bougie-guided, laryngeal mask airway-ProSeal™ placement technique in anaesthetized patients.

Authors:  Aaron M Joffe; Kristopher M Schroeder; John A Shepler; Richard E Galgon
Journal:  Indian J Anaesth       Date:  2012-05

2.  Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.

Authors:  C Frerk; V S Mitchell; A F McNarry; C Mendonca; R Bhagrath; A Patel; E P O'Sullivan; N M Woodall; I Ahmad
Journal:  Br J Anaesth       Date:  2015-11-10       Impact factor: 9.166

3.  Comparison of videolaryngoscope-guided versus standard digital insertion techniques of the ProSeal™ laryngeal mask airway: a prospective randomized study.

Authors:  Ulku Ozgul; Feray Akgul Erdil; Mehmet Ali Erdogan; Zekine Begec; Cemil Colak; Aytac Yucel; Mahmut Durmus
Journal:  BMC Anesthesiol       Date:  2019-12-30       Impact factor: 2.217

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.