Literature DB >> 1960252

Reliability of pulpal blood-flow measurements utilizing laser Doppler flowmetry.

D S Ramsay1, J Artun, S S Martinen.   

Abstract

Pulpal blood flow can now be measured non-invasively in the clinic utilizing laser Doppler flowmetry. The purpose of our study was to test (1) whether the position of the measurement probe on the tooth affects blood-flow measurements and (2) whether measurements from identical locations vary over time. Blood flow of one maxillary central incisor was measured in each of 13 volunteers. Measurements were recorded at five different locations on the labial surface of each tooth. Four measurement sessions were performed, and two sets of measurements were recorded at each session. Custom-made splints ensured accurate and reproducible positioning of the measurement probe at each session. Spatial position of the probe had a clear effect on the pulpal blood-flow measurements (p less than 0.0001). Measurements made at incisal and gingival locations were less and greater (p less than 0.05), respectively, than those made at central locations. Measurements from various mesio-distal locations did not differ (p greater than 0.05) when made at the same height on the tooth. Pulpal blood-flow measurements recorded at a given site were not consistent across all of the testing sessions (p less than 0.0001). Our data suggest that reliable interpretation of longitudinal measurements of pulpal blood flow obtained with laser Doppler flowmetry requires accurate repositioning of the measurement probe. In addition, an adequate control condition should be included to account for bias due to temporal variation.

Mesh:

Year:  1991        PMID: 1960252     DOI: 10.1177/00220345910700110601

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  6 in total

1.  Assessment of pulpal vitality using laser speckle imaging.

Authors:  Charles Stoianovici; Petra Wilder-Smith; Bernard Choi
Journal:  Lasers Surg Med       Date:  2011-09       Impact factor: 4.025

2.  The use of laser Doppler flowmetry in paediatric dentistry.

Authors:  H Roeykens; R De Moor
Journal:  Eur Arch Paediatr Dent       Date:  2011-04

3.  Diurnal variations and pulpal status: is there a need for FFT besides LDF?

Authors:  Herman J J Roeykens; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2018-06-13       Impact factor: 3.161

4.  Laser Doppler flowmetry: reproducibility, reliability, and diurnal blood flow variations.

Authors:  Herman J J Roeykens; Ellen Deschepper; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2016-05-16       Impact factor: 3.161

5.  Dental pulp testing: a review.

Authors:  Eugene Chen; Paul V Abbott
Journal:  Int J Dent       Date:  2009-11-12

6.  The effect of exercise on pulpal and gingival blood flow in physically active and inactive subjects as assessed by laser Doppler.

Authors:  Ec Lobo; Smt Nguyen; Ma Pogrel
Journal:  Open Dent J       Date:  2012-03-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.