Literature DB >> 19598224

Accurate and precise determination of isotopic ratios by MC-ICP-MS: a review.

Lu Yang1.   

Abstract

For many decades the accurate and precise determination of isotope ratios has remained a very strong interest to many researchers due to its important applications in earth, environmental, biological, archeological, and medical sciences. Traditionally, thermal ionization mass spectrometry (TIMS) has been the technique of choice for achieving the highest accuracy and precision. However, recent developments in multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) have brought a new dimension to this field. In addition to its simple and robust sample introduction, high sample throughput, and high mass resolution, the flat-topped peaks generated by this technique provide for accurate and precise determination of isotope ratios with precision reaching 0.001%, comparable to that achieved with TIMS. These features, in combination with the ability of the ICP source to ionize nearly all elements in the periodic table, have resulted in an increased use of MC-ICP-MS for such measurements in various sample matrices. To determine accurate and precise isotope ratios with MC-ICP-MS, utmost care must be exercised during sample preparation, optimization of the instrument, and mass bias corrections. Unfortunately, there are inconsistencies and errors evident in many MC-ICP-MS publications, including errors in mass bias correction models. This review examines "state-of-the-art" methodologies presented in the literature for achievement of precise and accurate determinations of isotope ratios by MC-ICP-MS. Some general rules for such accurate and precise measurements are suggested, and calculations of combined uncertainty of the data using a few common mass bias correction models are outlined.

Entities:  

Year:  2009        PMID: 19598224     DOI: 10.1002/mas.20251

Source DB:  PubMed          Journal:  Mass Spectrom Rev        ISSN: 0277-7037            Impact factor:   10.946


  11 in total

1.  Distance-of-Flight Mass Spectrometry with IonCCD Detection and an Inductively Coupled Plasma Source.

Authors:  Elise A Dennis; Steven J Ray; Christie G Enke; Alexander W Gundlach-Graham; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2015-11-09       Impact factor: 3.109

2.  Sr-Nd-Hf isotopic analysis of reference materials and natural and anthropogenic particulate matter sources: Implications for accurately tracing North African dust in complex urban atmospheres.

Authors:  Sourav Das; Brent V Miller; Joseph Prospero; Shankararaman Chellam
Journal:  Talanta       Date:  2022-01-19       Impact factor: 6.057

3.  Combining Isotope Dilution and Standard Addition-Elemental Analysis in Complex Samples.

Authors:  Christine Brauckmann; Axel Pramann; Olaf Rienitz; Alexander Schulze; Pranee Phukphatthanachai; Jochen Vogl
Journal:  Molecules       Date:  2021-04-30       Impact factor: 4.411

4.  Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr.

Authors:  Monika Horsky; Johanna Irrgeher; Thomas Prohaska
Journal:  Anal Bioanal Chem       Date:  2016-01       Impact factor: 4.142

Review 5.  Cu Isotopic Composition in Surface Environments and in Biological Systems: A Critical Review.

Authors:  Zhuhong Wang; Jiubin Chen; Ting Zhang
Journal:  Int J Environ Res Public Health       Date:  2017-05-18       Impact factor: 3.390

6.  Use of Lead Isotopic Ratios as Geographical Tracer for Lambrusco PDO Wines.

Authors:  Lisa Lancellotti; Simona Sighinolfi; Andrea Marchetti; Lorenzo Tassi
Journal:  Molecules       Date:  2020-04-02       Impact factor: 4.411

7.  Identification of two-dimensional copper signatures in human blood for bladder cancer with machine learning.

Authors:  Weichao Wang; Xian Liu; Changwen Zhang; Fei Sheng; Shanjun Song; Penghui Li; Shaoqing Dai; Bin Wang; Dawei Lu; Luyao Zhang; Xuezhi Yang; Zhihong Zhang; Sijin Liu; Aiqian Zhang; Qian Liu; Guibin Jiang
Journal:  Chem Sci       Date:  2022-01-11       Impact factor: 9.825

8.  Deciphering the lithium ion movement in lithium ion batteries: determination of the isotopic abundances of 6Li and 7Li.

Authors:  Marcel Diehl; Marco Evertz; Martin Winter; Sascha Nowak
Journal:  RSC Adv       Date:  2019-04-16       Impact factor: 4.036

9.  Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS.

Authors:  Nikitha Susan Saji; Daniel Wielandt; Chad Paton; Martin Bizzarro
Journal:  J Anal At Spectrom       Date:  2016-07-01       Impact factor: 4.023

10.  Cu isotopic signature in blood serum of liver transplant patients: a follow-up study.

Authors:  Sara Lauwens; Marta Costas-Rodríguez; Hans Van Vlierberghe; Frank Vanhaecke
Journal:  Sci Rep       Date:  2016-07-29       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.