Implementation of graphic user interface screen capture solution for workflow assessment of abdominal MR examinations valuable tool to analyze discrepancies in expected and experienced MR table time.

Christopher J Roth1, Daniel T Boll, Yen W Chea, Lisa K Wall, Elmar M Merkle.   

Abstract

RATIONALE AND
OBJECTIVES: The aim of this study was to assess if graphical user interface screen-capture software applied to a magnetic resonance (MR) hardware console could nonintrusively allow the analysis of discrepancies between expected and experienced MR table time.
MATERIALS AND METHODS: Individual MR examination acquisition processes were captured in audio-video interleave streams for 10 patients who underwent comprehensive liver MR imaging. These audio-video streams were dissected into periods of true image data acquisition, scanner activity without direct image data acquisition, and scanner inactivity.
RESULTS: Total expected time required for standardized liver MR image acquisition was estimated at 15 minutes. Experienced table times varied highly, ranging from 19:00 to 58:08 minutes. Image data acquisition occurred during approximately 58% (range, 43.3%-73.7%) of overall table time. Image data were obtained approximately 77% (range, 65.6%-87.0%) of the time the scanner spent active.
CONCLUSION: Graphical user interface screen-capture software installed on an MR console nonintrusively revealed significant periods of table time spent not obtaining true image data and explained discrepancies between expected and experienced MR table times. Table-time calculations using Digital Imaging and Communications in Medicine image headers and scanner-logged time stamps are underestimations of true table time because they do not take into account some scanner activities not directly leading to image formation.

Entities:  

Mesh:

Year:  2009        PMID: 19596590     DOI: 10.1016/j.acra.2009.05.009

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  3 in total

1.  Workflow Lexicons in Healthcare: Validation of the SWIM Lexicon.

Authors:  Chris Meenan; Bradley Erickson; Nancy Knight; Jewel Fossett; Elizabeth Olsen; Prerna Mohod; Joseph Chen; Steve G Langer
Journal:  J Digit Imaging       Date:  2017-06       Impact factor: 4.056

2.  Factors predicting the time-length variability of identically protocoled MRI exams.

Authors:  Gregory D Avey; Daryn S Belden; Ryan D Zea; John-Paul J Yu
Journal:  J Magn Reson Imaging       Date:  2019-01-13       Impact factor: 4.813

3.  Free-Breathing Liver Magnetic Resonance Imaging With Respiratory Frequency-Modulated Continuous-Wave Radar-Trigger Technique: A Preliminary Study.

Authors:  Xinyue Liang; Zhenghong Bi; Chun Yang; Ruofan Sheng; Xinyuan Xia; Zheng Zhang; Yongming Dai; Mengsu Zeng
Journal:  Front Oncol       Date:  2022-06-01       Impact factor: 5.738

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.