Literature DB >> 19595647

Breath acetone analysis with miniaturized sample preparation device: in-needle preconcentration and subsequent determination by gas chromatography-mass spectroscopy.

Ikuo Ueta1, Yoshihiro Saito, Masahiko Hosoe, Mitsuyoshi Okamoto, Hironobu Ohkita, Shingoro Shirai, Hiroshi Tamura, Kiyokatsu Jinno.   

Abstract

A new approach to the determination of human breath acetone with particle-packed sample preparation needle was developed. The extraction needle was packed with a copolymer of methacrylic acid and ethylene glycol dimethacrylate as the extraction medium. For the analysis of breath sample, exhaled breath was collected in a sampling bag, and 50 mL of the breath sample was extracted with the needle-type sample preparation device followed by analysis using gas chromatography-mass spectrometry (GC-MS). After the optimization of several basic extraction conditions for standard acetone samples, breath acetone concentration taken from controlled type-2 diabetic patients was determined. Furthermore, time variations of breath and urine acetone of four healthy individuals under fasting conditions were measured. Urine sample was collected in glass vial, and urine acetone concentration was also determined with the extraction needle by analyzing the corresponding headspace gas. The results demonstrated that the particle-packed extraction needle showed an excellent extraction performance for acetone in both breath and urine headspace samples, and that there is a clear correlation between the concentration of breath acetone and HbA1c level of controlled type-2 diabetic patients. The breath acetone level in controlled diabetic patients was in the range between 0.19 and 0.66 ppmv, where its concentration in medically untreated type-2 patient was 0.92 and 1.20 ppmv. The breath acetone concentration in healthy male was increased to 5.66 ppmv under the 24 h of fasting test, and a high correlation between the breath and urine acetone concentration was also observed. On the basis of the above results, the potential applications of the proposed method to the diagnosis of diabetes and/or ketoacidosis were suggested.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19595647     DOI: 10.1016/j.jchromb.2009.06.039

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  9 in total

1.  A Negative Correlation Between Blood Glucose and Acetone Measured in Healthy and Type 1 Diabetes Mellitus Patient Breath.

Authors:  Artur Rydosz
Journal:  J Diabetes Sci Technol       Date:  2015-02-17

Review 2.  Significance of Exhaled Breath Test in Clinical Diagnosis: A Special Focus on the Detection of Diabetes Mellitus.

Authors:  Souvik Das; Saurabh Pal; Madhuchhanda Mitra
Journal:  J Med Biol Eng       Date:  2016-10-11       Impact factor: 1.553

3.  A Novel Medical E-Nose Signal Analysis System.

Authors:  Lu Kou; David Zhang; Dongxu Liu
Journal:  Sensors (Basel)       Date:  2017-04-05       Impact factor: 3.576

4.  Design of a novel filter paper based construct for rapid analysis of acetone.

Authors:  Sajid Rauf; Yaqeen Ali; Sabir Hussain; Fakhar Ullah; Akhtar Hayat
Journal:  PLoS One       Date:  2018-07-06       Impact factor: 3.240

5.  Micropreconcentrator in LTCC Technology with Mass Spectrometry for the Detection of Acetone in Healthy and Type-1 Diabetes Mellitus Patient Breath.

Authors:  Artur Rydosz
Journal:  Metabolites       Date:  2014-10-10

Review 6.  Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring.

Authors:  Valentine Saasa; Thomas Malwela; Mervyn Beukes; Matlou Mokgotho; Chaun-Pu Liu; Bonex Mwakikunga
Journal:  Diagnostics (Basel)       Date:  2018-01-31

7.  Transilient Response to Acetone Gas Using the Interlocking p+n Field-Effect Transistor Circuit.

Authors:  Xinyuan Zhou; Jinxiao Wang; Zhou Wang; Yuzhi Bian; Ying Wang; Ning Han; Yunfa Chen
Journal:  Sensors (Basel)       Date:  2018-06-12       Impact factor: 3.576

8.  Highly Sensitive Acetone Gas Sensor Based on g-C₃N₄ Decorated MgFe₂O₄ Porous Microspheres Composites.

Authors:  Run Zhang; Yan Wang; Zhanying Zhang; Jianliang Cao
Journal:  Sensors (Basel)       Date:  2018-07-10       Impact factor: 3.576

Review 9.  Sensors for Enhanced Detection of Acetone as a Potential Tool for Noninvasive Diabetes Monitoring.

Authors:  Artur Rydosz
Journal:  Sensors (Basel)       Date:  2018-07-16       Impact factor: 3.576

  9 in total