Literature DB >> 19593133

Effectiveness of midurethral slings in intrinsic sphincteric-related stress urinary incontinence.

Yik N Lim1, Peter L Dwyer.   

Abstract

PURPOSE OF REVIEW: Previous literature has shown that urodynamic evidence of intrinsic sphincter deficiency (ISD) decreases the surgical success of traditional antistress incontinence surgeries. The aim of this review is to assess recent evidence on the effectiveness of the increasingly popular midurethral slings (MUS) in women with ISD and stress urinary incontinence. RECENT
FINDINGS: Using the ISD definition of maximum urethral closure pressure of 20 cm H2O or less and/or abdominal/valsalva leak point pressure of 60 cm H2O or less, current literature would suggest that the effectiveness of retropubic MUS is reduced but remained acceptable in women with stress urinary incontinence and ISD. There are conflicting data on whether coexisting poor urethral mobility could further compromise surgical success. Of note, there is now emerging evidence to suggest that transobturator tapes are associated with much higher failure rates in this setting and retropubic MUS should be used instead. Currently, there is too little data on the new single-incision mini-slings for any recommendation of use in women with stress incontinence with good or poor intrinsic urethral function.
SUMMARY: MUS is an effective treatment for stress urinary incontinence. However, when urodynamic evidence of ISD is present, the retropubic approach may be preferable to the transobturator approach.

Entities:  

Mesh:

Year:  2009        PMID: 19593133     DOI: 10.1097/GCO.0b013e32832fd268

Source DB:  PubMed          Journal:  Curr Opin Obstet Gynecol        ISSN: 1040-872X            Impact factor:   1.927


  4 in total

Review 1.  Retropubic versus transobturator midurethral synthetic slings: does one sling fit all?

Authors:  Sarah E McAchran
Journal:  Curr Urol Rep       Date:  2010-09       Impact factor: 3.092

2.  Usefulness of retropubic tape for recurrent stress incontinence after transobturator tape failure.

Authors:  Jordi Sabadell; Jose L Poza; Antonio Esgueva; Juan C Morales; Jose L Sánchez-Iglesias; Jordi Xercavins
Journal:  Int Urogynecol J       Date:  2011-07-06       Impact factor: 2.894

3.  Minimum 1-year results of mesh spiral-sling procedure in managing refractory and primary disabling stress urinary incontinence.

Authors:  Sinasi Yavuz Önol; Osman Sevket; Fikret Fatih Önol; Remzi Erdem; Abdülkadir Tepeler
Journal:  Int Urogynecol J       Date:  2014-08-19       Impact factor: 2.894

4.  Efficacy of urodynamic studies in predicting long-term outcomes of the transobturator tape: do they augment clinical assessment?

Authors:  Stefanie M Croghan; Grainne Costigan; Niall O'Dwyer; Eoin MacCraith; Gerry Lennon
Journal:  Cent European J Urol       Date:  2019-09-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.