Literature DB >> 19591239

Influence of direct laser fabrication implant topography on type IV bone: a histomorphometric study in humans.

Jamil Awad Shibli1, Carlo Mangano, Susana D'avila, Adriano Piattelli, Gabriele E Pecora, Francesco Mangano, Tatiana Onuma, Luciana A Cardoso, Daniel Sanchez Ferrari, Kelly C Aguiar, Giovanna Iezzi.   

Abstract

The aim of this histologic study was to evaluate the influence of the direct laser fabrication (DFL) surface topography on bone-to-implant contact (BIC%), on bone density in the threaded area (BA%) as well as bone density outside the threaded area (BD%) in type IV bone after 8 weeks of unloaded healing. Thirty patients (mean age 51.34 +/- 3.06 years) received 1 micro-implant (2.5-mm diameter and 6-mm length) each during conventional implant surgery in the posterior maxilla. Thirty micro-implants with three topographies were evaluated: 10 machined (cpTi); 10 sandblasted and acid etched surface (SAE) and 10 DFL micro-implants. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for histomorphometric analysis. Four micro-implants (2 cpTi, 1 SAE and 1DLF) showed no osseointegration after the healing period. Histometric evaluation indicated that the mean BIC% was higher for the DFL and SAE surfaces (p = 0.0002). The BA% was higher for the DFL surface, although there was no difference with the SAE surface. The BD% was similar for all topographies (p > 0.05). Data suggest that the DFL and SAE surfaces presented a higher bone-to-implant contact rate compared with cpTi surfaces under unloaded conditions, after a healing period of 8 weeks. Copyright 2009 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19591239     DOI: 10.1002/jbm.a.32566

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  16 in total

1.  Prospective clinical evaluation of 201 direct laser metal forming implants: results from a 1-year multicenter study.

Authors:  Carlo Mangano; Francesco Mangano; Jamil Awad Shibli; Giuseppe Luongo; Michele De Franco; Francesco Briguglio; Michele Figliuzzi; Tammaro Eccellente; Carmine Rapani; Michele Piombino; Aldo Macchi
Journal:  Lasers Med Sci       Date:  2011-04-26       Impact factor: 3.161

2.  Custom-made, selective laser sintering (SLS) blade implants as a non-conventional solution for the prosthetic rehabilitation of extremely atrophied posterior mandible.

Authors:  F Mangano; M Bazzoli; L Tettamanti; D Farronato; M Maineri; A Macchi; C Mangano
Journal:  Lasers Med Sci       Date:  2012-09-14       Impact factor: 3.161

3.  Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients.

Authors:  Francesco Guido Mangano; Michele De Franco; Alberto Caprioglio; Aldo Macchi; Adriano Piattelli; Carlo Mangano
Journal:  Lasers Med Sci       Date:  2013-03-15       Impact factor: 3.161

4.  Lateral static overload on immediately restored implants decreases the osteocyte index in peri-implant bone: a secondary analysis of a pre-clinical study in dogs.

Authors:  Celson Domingos de Calais; Dimorvan Bordin; Adriano Piattelli; Giovanna Iezzi; Alexandre Negretto; Jamil A Shibli
Journal:  Clin Oral Investig       Date:  2020-11-05       Impact factor: 3.573

5.  Surface alterations of zirconia and titanium substrates after Er,Cr:YSGG irradiation.

Authors:  Persio Vasconcelos Miranda; José Augusto Rodrigues; Alberto Blay; Jamil Awad Shibli; Alessandra Cassoni
Journal:  Lasers Med Sci       Date:  2014-01-16       Impact factor: 3.161

Review 6.  Direct metal laser sintering titanium dental implants: a review of the current literature.

Authors:  F Mangano; L Chambrone; R van Noort; C Miller; P Hatton; C Mangano
Journal:  Int J Biomater       Date:  2014-12-01

7.  Maxillary overdentures supported by four splinted direct metal laser sintering implants: a 3-year prospective clinical study.

Authors:  Francesco Mangano; Fabrizia Luongo; Jamil Awad Shibli; Sukumaran Anil; Carlo Mangano
Journal:  Int J Dent       Date:  2014-12-14

8.  Scanning Electron Microscope (SEM) Evaluation of the Interface between a Nanostructured Calcium-Incorporated Dental Implant Surface and the Human Bone.

Authors:  Francesco Mangano; Mario Raspanti; Hassan Maghaireh; Carlo Mangano
Journal:  Materials (Basel)       Date:  2017-12-17       Impact factor: 3.623

9.  Biological width around one- and two-piece implants retrieved from human jaws.

Authors:  Ricardo Judgar; Gabriela Giro; Elton Zenobio; Paulo G Coelho; Magda Feres; Jose A Rodrigues; Carlo Mangano; Giovanna Iezzi; Adriano Piattelli; Jamil Awad Shibli
Journal:  Biomed Res Int       Date:  2014-06-23       Impact factor: 3.411

10.  Surface characterization and in vivo evaluation of laser sintered and machined implants followed by resorbable-blasting media process: A study in sheep.

Authors:  Michelle Bowers; Daniel Yoo; Charles Marin; Luiz Gil; Nour Shabaka; Matt Goldstein; Malvin Janal; Nick Tovar; Ronaldo Hirata; Estevam Bonfante; Paulo Coelho
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-03-01
View more