Literature DB >> 19590657

Utility of the Gyrus open forceps in hepatic parenchymal transection.

Matthew R Porembka1, M B Majella Doyle, Nicholas A Hamilton, Peter O Simon, Steven M Strasberg, David C Linehan, William G Hawkins.   

Abstract

OBJECTIVE: This study aimed to evaluate if the Gyrus open forceps is a safe and efficient tool for hepatic parenchymal transection.
BACKGROUND: Blood loss during hepatic transection remains a significant risk factor for morbidity and mortality associated with liver surgery. Various electrosurgical devices have been engineered to reduce blood loss. The Gyrus open forceps is a bipolar cautery device which has recently been introduced into hepatic surgery.
METHODS: We conducted a single-institution, retrospective review of all liver resections performed from November 2005 through November 2007. Patients undergoing resection of at least two liver segments where the Gyrus was the primary method of transection were included. Patient charts were reviewed; clinicopathological data were collected.
RESULTS: Of the 215 open liver resections performed during the study period, 47 patients met the inclusion criteria. Mean patient age was 61 years; 34% were female. The majority required resection for malignant disease (94%); frequent indications included colorectal metastasis (66%), hepatocellular carcinoma (6%) and cholangiocarcinoma (4%). Right hemihepatectomy (49%), left hemihepatectomy (13%) and right trisectionectomy (13%) were the most frequently performed procedures. A total of 26 patients (55%) underwent a major ancillary procedure concurrently. There were no operative mortalities. Median operative time was 220 min (range 97-398 min). Inflow occlusion was required in nine patients (19%) for a median time of 12 min (range 3-30 min). Median total estimated blood loss was 400 ml (range 10-2000 ml) and 10 patients (21%) required perioperative transfusion. All patients had macroscopically negative margins. Median length of stay was 8 days. Two patients (4%) had clinically significant bile leak. The 30-day postoperative mortality was zero.
CONCLUSIONS: Use of the Gyrus open forceps appears to be a safe and efficient manner of hepatic parenchymal transection which allows rapid transection with acceptable blood loss, a low rate of perioperative transfusion, and minimal postoperative bile leak.

Entities:  

Keywords:  Gyrus device; hepatic transection; liver surgery

Year:  2009        PMID: 19590657      PMCID: PMC2697894          DOI: 10.1111/j.1477-2574.2009.00048.x

Source DB:  PubMed          Journal:  HPB (Oxford)        ISSN: 1365-182X            Impact factor:   3.647


  26 in total

1.  Incidence and management of bile leakage after hepatic resection for malignant hepatic tumors.

Authors:  Shogo Tanaka; Kazuhiro Hirohashi; Hiromu Tanaka; Taichi Shuto; Sang Hun Lee; Shoji Kubo; Shigekazu Takemura; Takatsugu Yamamoto; Takahiro Uenishi; Hiroaki Kinoshita
Journal:  J Am Coll Surg       Date:  2002-10       Impact factor: 6.113

2.  Incidence of bile leakage after three types of hepatic parenchymal transection.

Authors:  Hisashi Nakayama; Hideki Masuda; Masahiko Shibata; Sadao Amano; Masahiro Fukuzawa
Journal:  Hepatogastroenterology       Date:  2003 Sep-Oct

3.  Hepatic resection using stapling devices.

Authors:  Hironori Kaneko; Yuichiro Otsuka; Sumito Takagi; Masaru Tsuchiya; Akira Tamura; Tadaaki Shiba
Journal:  Am J Surg       Date:  2004-02       Impact factor: 2.565

4.  Early experience employing a linear hepatic parenchyma coagulation device.

Authors:  Cord Sturgeon; W Scott Helton; Amit Lamba; Gregorio Chejfec; N Joseph Espat
Journal:  J Hepatobiliary Pancreat Surg       Date:  2003

5.  Use of a bipolar vessel-sealing device for parenchymal transection during liver surgery.

Authors:  Steven M Strasberg; Jeffrey A Drebin; David Linehan
Journal:  J Gastrointest Surg       Date:  2002 Jul-Aug       Impact factor: 3.452

6.  A simplified technique for hepatic resection: the crush method.

Authors:  T Y Lin
Journal:  Ann Surg       Date:  1974-09       Impact factor: 12.969

7.  Bile leakage after hepatic resection.

Authors:  Y Yamashita; T Hamatsu; T Rikimaru; S Tanaka; K Shirabe; M Shimada; K Sugimachi
Journal:  Ann Surg       Date:  2001-01       Impact factor: 12.969

8.  Improvement in perioperative outcome after hepatic resection: analysis of 1,803 consecutive cases over the past decade.

Authors:  William R Jarnagin; Mithat Gonen; Yuman Fong; Ronald P DeMatteo; Leah Ben-Porat; Sarah Little; Carlos Corvera; Sharon Weber; Leslie H Blumgart
Journal:  Ann Surg       Date:  2002-10       Impact factor: 12.969

9.  Perioperative blood transfusion and determinants of survival after liver resection for metastatic colorectal carcinoma.

Authors:  C B Rosen; D M Nagorney; H F Taswell; S L Helgeson; D M Ilstrup; J A van Heerden; M A Adson
Journal:  Ann Surg       Date:  1992-10       Impact factor: 12.969

10.  Influence of transfusions on perioperative and long-term outcome in patients following hepatic resection for colorectal metastases.

Authors:  David A Kooby; Jennifer Stockman; Leah Ben-Porat; Mithat Gonen; William R Jarnagin; Ronald P Dematteo; Scott Tuorto; David Wuest; Leslie H Blumgart; Yuman Fong
Journal:  Ann Surg       Date:  2003-06       Impact factor: 12.969

View more
  2 in total

1.  Radiofrequency vessel-sealing system versus the clamp-crushing technique in liver transection: results of a prospective randomized study on 100 consecutive patients.

Authors:  Andrea Muratore; Alfredo Mellano; Giuseppe Tarantino; Patrizia Marsanic; Michele De Simone; Fabrizio Di Benedetto
Journal:  HPB (Oxford)       Date:  2014-01-28       Impact factor: 3.647

2.  Bleeding in Hepatic Surgery: Sorting through Methods to Prevent It.

Authors:  Fabrizio Romano; Mattia Garancini; Fabio Uggeri; Luca Degrate; Luca Nespoli; Luca Gianotti; Angelo Nespoli; Franco Uggeri
Journal:  HPB Surg       Date:  2012-11-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.