Literature DB >> 19589422

Imaging of the complications of peripherally inserted central venous catheters.

S S H Amerasekera1, C M Jones, R Patel, M J Cleasby.   

Abstract

Peripherally inserted central catheters (PICC) are widely used to provide central venous access, often in chronically ill patients with long-term intravenous access requirements. There are a number of significant complications related to both insertion and maintenance of PICC lines, including catheter malposition, migration, venous thrombosis, and line fracture. The incidence of these complications is likely to rise as the number of patients undergoing intravenous outpatient therapy increases, with a corresponding rise in radiologist input. This paper provides an overview of the relevant peripheral and central venous anatomy, including anatomical variations, and outlines the complications of PICC lines. Imaging examples demonstrate the range of radiological findings seen in these complications.

Entities:  

Mesh:

Year:  2009        PMID: 19589422     DOI: 10.1016/j.crad.2009.02.021

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  31 in total

1.  Risk factors for venous thrombosis associated with peripherally inserted central venous catheters.

Authors:  Longfang Pan; Qianru Zhao; Xiangmei Yang
Journal:  Int J Clin Exp Med       Date:  2014-12-15

2.  Endovascular technique using a snare and suture for retrieving a migrated peripherally inserted central catheter in the left pulmonary artery.

Authors:  Hiroki Teragawa; Takashi Sueda; Yuichi Fujii; Hiroaki Takemoto; Yasushi Toyota; Shuichi Nomura; Keigo Nakagawa
Journal:  World J Cardiol       Date:  2013-09-26

3.  Persistent hiccup caused by peripherally inserted central catheter migration.

Authors:  Yeling Zhang; Haiping Jiang; Lili Wei; Hongsheng Yu
Journal:  J Anesth       Date:  2011-06-28       Impact factor: 2.078

4.  Radiologist variability in assessing the position of the cavoatrial junction on chest radiographs.

Authors:  Tze Y Chan; Andrew England; Sara M Meredith; Richard G McWilliams
Journal:  Br J Radiol       Date:  2016-07-12       Impact factor: 3.039

5.  An Uncommon Complication of a Common Procedure.

Authors:  Demetrios N Moris; Adamantios Michalinos; Spiridon Vernadakis
Journal:  Indian J Surg       Date:  2014-05-09       Impact factor: 0.656

6.  Peripherally inserted central venous catheter safety in burn care: a single-center retrospective cohort review.

Authors:  Ryan E Austin; Shahriar Shahrokhi; Siavash Bolourani; Marc G Jeschke
Journal:  J Burn Care Res       Date:  2015 Jan-Feb       Impact factor: 1.845

7.  An in vitro study comparing a peripherally inserted central catheter to a conventional central venous catheter: no difference in static and dynamic pressure transmission.

Authors:  Heath E Latham; Timothy T Dwyer; Bethene L Gregg; Steven Q Simpson
Journal:  BMC Anesthesiol       Date:  2010-10-12       Impact factor: 2.217

8.  Peripherally inserted central catheter placement in cancer patients with profound thrombocytopaenia: a prospective analysis.

Authors:  Julien Potet; Alphonse Thome; Emmanuel Curis; François-Xavier Arnaud; Gabrielle Weber-Donat; Laura Valbousquet; Evelyne Peroux; Eric Flor; Christophe Dody; Johanna Konopacki; Jean Valère Malfuson; Cecile Cartry; Marion Lahutte; Thierry de Revel; Jacques Baccialone; Christophe A Teriitehau
Journal:  Eur Radiol       Date:  2013-02-26       Impact factor: 5.315

9.  Congenital systemic-pulmonary collateral vein unexpectedly noticed after central venous catheter insertion.

Authors:  Hiroshi Miura; Takuji Yamagami; Rika Yoshimatsu; Tomohiro Matsumoto; Tsunehiko Nishimura
Journal:  Ann Vasc Dis       Date:  2012

10.  Tip malposition of peripherally inserted central catheters: a prospective randomized controlled trial to compare bedside insertion to fluoroscopically guided placement.

Authors:  Frédéric Glauser; Stephane Breault; Fabio Rigamonti; Charalampos Sotiriadis; Anne-Marie Jouannic; Salah D Qanadli
Journal:  Eur Radiol       Date:  2016-12-12       Impact factor: 5.315

View more