Literature DB >> 19578611

[Comparative study between MBI (FICE) and magnification chromoendoscopy with indigo carmine in the differential diagnosis of neoplastic and non-neoplastic lesions of the colorectum].

Carlos Eduardo Oliveira dos Santos1, Júlio Carlos Pereira-Lima, César Vivian Lopes, Daniele Malaman, Artur A Parada, Antônio David Salomão.   

Abstract

CONTEXT: Multiband imaging (MBI)/Fuji Intelligent Color Enhancement (FICE) is a spectral image processing technology that helps in vivo diagnosis of colorectal neoplasias.
OBJECTIVE: To compare the diagnostic accuracy of the magnification with either the electronic chromoendoscopy or indigo carmine dye in the differential diagnosis of neoplastic and non-neoplastic colorectal lesions.
METHODS: Seventy five patients with 157 colorectal lesions were prospectively evaluated. The capillary pattern, as well as the pit pattern according to the Kudo classification, of colorectal lesions were evaluated by means of the FICE system. Absence and presence of meshed capillary networks were labeled as non-neoplastic and neoplastic lesions, respectively. Afterwards, indigo carmine 0.8% was instilled and a new evaluation of the pit pattern was carried out.
RESULTS: One hundred and sixteen of the 157 lesions were classified as positive meshed capillary network, 115 of them were confirmed histologically as neoplasia. Other 32 lesions out of 41 with negative meshed capillary network were non-neoplastic. Sensitivity, specificity and accuracy were, respectively, 92.7%, 97% and 93.6%. Pit patterns I and II were confirmed as non-neoplastic lesions, and patterns III to V were confirmed as neoplasias. Sensitivity, specificity and accuracy for the electronic chromoendoscopy were, respectively, 94.4%, 97% and 94.9%. Meanwhile, the figures for the magnification with indigo carmine were, respectively, 97.6%, 93.9% and 96.8%.
CONCLUSIONS: Both methods, either the MBI/FICE system or the use of indigo carmine dye with magnification, achieved a high accuracy for the differential diagnosis between neoplastic and non-neoplastic colorectal lesions.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19578611     DOI: 10.1590/s0004-28032009000200007

Source DB:  PubMed          Journal:  Arq Gastroenterol        ISSN: 0004-2803


  4 in total

1.  Observer agreement for diagnosis of colorectal lesions with analysis of the vascular pattern by image-enhanced endoscopy.

Authors:  Carlos Eduardo Oliveira Dos Santos; Horácio Joaquin Perez; Klaus Mönkemüller; Daniele Malaman; César Vivian Lopes; Júlio Carlos Pereira-Lima
Journal:  Endosc Int Open       Date:  2015-04-14

Review 2.  Application and Efficacy of Super-Magnifying Endoscopy for the Lower Intestinal Tract.

Authors:  Naoki Hosoe; Haruhiko Ogata
Journal:  Clin Endosc       Date:  2016-01-28

3.  Hyoscine butylbromide for colorectal polyp detection: prospective, randomized, placebo-controlled trial.

Authors:  Carlos Eduardo Oliveira Dos Santos; Hamilton Moreira; Julio Carlos Pereira-Lima; Carmen Australia Paredes Marcondes Ribas; Fernanda de Quadros Onófrio; Alexandre Eduardo Augusti Czecko; Rafael Koerich Ramos; Caroline Aragão de Carvalho
Journal:  Clinics (Sao Paulo)       Date:  2017-07       Impact factor: 2.365

4.  Digital chromoendoscopy for diagnosis of diminutive colorectal lesions.

Authors:  Carlos Eduardo Oliveira Dos Santos; Daniele Malaman; César Vivian Lopes; Júlio Carlos Pereira-Lima; Artur Adolfo Parada
Journal:  Diagn Ther Endosc       Date:  2012-10-03
  4 in total