Literature DB >> 19577652

Bootstrap quantification of cardiac pulsation artifact in DTI.

SungWon Chung1, Blandine Courcot, Michael Sdika, Kristin Moffat, Caroline Rae, Roland G Henry.   

Abstract

While several studies have shown the benefit of cardiac gating in diffusion MRI with single-shot EPI acquisition, cardiac gating is still not commonly used. This is probably because it requires additional time and many investigators may not be convinced that cardiac gating is worth the extra effort. Here, we tested a clinically feasible protocol with a minimal increase in scan time, and quantified the effect of cardiac gating under partial or full Fourier acquisition. Eight volunteers were scanned on a 3 T scanner with a SENSE 8-channel head coil. Diffusion-weighted, single-shot spin-echo EPI images were acquired along 32 gradient directions, with or without cardiac gating and with partial or full Fourier acquisition. Vectorcardiography (VCG) was used to trigger acquisition at a minimum delay (30 ms). The uncertainties of DTI derived parameters were estimated using residual bootstrap. With partial Fourier, cardiac gating reduced the uncertainties, and better efficiency in reducing DTI parameter variability was also achieved even allowing for the increase in total scan time. For full Fourier acquisition, minimum time gating slightly decreased the uncertainties but the efficiency was worse. A minimum trigger delay might not be the optimal scheme to avoid the majority of systole but it allows clinically acceptable scan times. We have demonstrated that cardiac gating, especially of partial Fourier acquisitions, can reduce the uncertainties of DTI derived parameters in a time-efficient manner.

Entities:  

Mesh:

Year:  2009        PMID: 19577652     DOI: 10.1016/j.neuroimage.2009.06.067

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  12 in total

1.  Reproducibility of Tract-based and Region-of-Interest DTI Analysis of Long Association Tracts.

Authors:  N Brandstack; T Kurki; J Laalo; T Kauko; O Tenovuo
Journal:  Clin Neuroradiol       Date:  2014-10-05       Impact factor: 3.649

2.  Effect of respiratory and cardiac gating on the major diffusion-imaging metrics.

Authors:  Hiroyuki Hamaguchi; Khin Khin Tha; Hiroyuki Sugimori; Mitsuhiro Nakanishi; Shin Nakagawa; Taro Fujiwara; Hirokazu Yoshida; Sayaka Takamori; Hiroki Shirato
Journal:  Neuroradiol J       Date:  2016-04-12

3.  Ambulatory pulse pressure, brain neuronal fiber integrity, and cerebral blood flow in older adults.

Authors:  Takashi Tarumi; Binu P Thomas; Ciwen Wang; Li Zhang; Jie Liu; Marcel Turner; Jonathan Riley; Nikita Tangella; Kyle B Womack; Diana R Kerwin; C Munro Cullum; Hanzhang Lu; Wanpen Vongpatanasin; David C Zhu; Rong Zhang
Journal:  J Cereb Blood Flow Metab       Date:  2017-12-08       Impact factor: 6.200

4.  Quantification of accuracy and precision of multi-center DTI measurements: a diffusion phantom and human brain study.

Authors:  Tong Zhu; Rui Hu; Xing Qiu; Michael Taylor; Yuen Tso; Constantin Yiannoutsos; Bradford Navia; Susumu Mori; Sven Ekholm; Giovanni Schifitto; Jianhui Zhong
Journal:  Neuroimage       Date:  2011-02-18       Impact factor: 6.556

5.  Effects of cardiac pulsation in diffusion tensor imaging of the rat brain.

Authors:  Sungheon Kim; Stephen Pickup; Harish Poptani
Journal:  J Neurosci Methods       Date:  2010-10-14       Impact factor: 2.390

6.  The impact of post-processing on spinal cord diffusion tensor imaging.

Authors:  Siawoosh Mohammadi; Patrick Freund; Thorsten Feiweier; Armin Curt; Nikolaus Weiskopf
Journal:  Neuroimage       Date:  2013-01-05       Impact factor: 6.556

7.  Retrospective correction of physiological noise in DTI using an extended tensor model and peripheral measurements.

Authors:  Siawoosh Mohammadi; Chloe Hutton; Zoltan Nagy; Oliver Josephs; Nikolaus Weiskopf
Journal:  Magn Reson Med       Date:  2012-08-30       Impact factor: 4.668

Review 8.  Searching for novel biomarkers using high resolution diffusion tensor imaging.

Authors:  Michael A Yassa
Journal:  J Alzheimers Dis       Date:  2011       Impact factor: 4.160

9.  Identical, but not the same: intra-site and inter-site reproducibility of fractional anisotropy measures on two 3.0T scanners.

Authors:  Christian Vollmar; Jonathan O'Muircheartaigh; Gareth J Barker; Mark R Symms; Pamela Thompson; Veena Kumari; John S Duncan; Mark P Richardson; Matthias J Koepp
Journal:  Neuroimage       Date:  2010-03-23       Impact factor: 6.556

10.  Investigating the need of triggering the acquisition for infant diffusion MRI: a quantitative study including bootstrap statistics.

Authors:  Lajos R Kozák; Szabolcs Dávid; Gábor Rudas; Zoltán Vidnyánszky; Alexander Leemans; Zoltán Nagy
Journal:  Neuroimage       Date:  2012-12-14       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.