Literature DB >> 19577057

Intraoperative bypass graft flow in intra-aortic balloon pump-supported patients: differences in arterial and venous sequential conduits.

Francesco Onorati1, Giuseppe Santarpino, Antonio Rubino, Lucia Cristodoro, Cristian Scalas, Attilio Renzulli.   

Abstract

BACKGROUND: The intra-aortic balloon pump is used worldwide as an anti-ischemic strategy. However, little is known about the modifications of the graft flowmetry during use of intra-aortic balloon pump.
METHODS: An observational study aimed at analyzing transit-time flow measurements during 1:1 intra-aortic balloon pump use and during its cessation in 138 consecutive patients using intra-aortic balloon pump before coronary artery bypass grafting (n = 442 graft segments) was reported.
RESULTS: In normally functioning grafts, the mean diastolic and mean blood flow improved significantly during 1:1 intra-aortic balloon pump use compared with during intra-aortic balloon pump cessation (P < .001), although mean and diastolic arterial pressures were significantly lower (P = .001). Arterial and sequential saphenous vein grafts showed greater improvements in mean diastolic and mean flow compared with single venous grafts. Surplus graft flow (defined as mean flow during 1:1 intra-aortic balloon pump use/mean flow with intra-aortic balloon pump off) was recorded (surplus graft flow > 1) during 1:1 intra-aortic balloon pump use in all normally functioning grafts, with higher values in single arterial or sequential saphenous vein grafts versus single venous grafts (both P < .001). In the 9 cases of graft failure, the mean diastolic, mean systolic, and mean flow were significantly lower and the pulsatility index greater, compared with normally functioning grafts (all P <or= .001). Blood flow did not change appreciably during 1:1 intra-aortic balloon pump use in failed bypass grafts; thus the surplus graft flow approached 1.
CONCLUSION: In this analysis, use of intra-aortic balloon pump was associated with improved diastolic and mean blood flow in bypass grafts. Arterial and sequential grafts were associated with greater improvements in blood flow and surplus graft flow. Graft failure was associated with poor transit-time flow results, high pulsatility index values, and absent surplus graft flow.

Entities:  

Mesh:

Year:  2009        PMID: 19577057     DOI: 10.1016/j.jtcvs.2008.11.044

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Surgical myocardial revascularization of patients with ischemic cardiomyopathy and severe left ventricular disfunction.

Authors:  André L Hovnanian; Alexandre de Matos Soeiro; Carlos Vicente Serrano; Sérgio Almeida de Oliveira; Fábio B Jatene; Noedir A G Stolf; José A F Ramires
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

2.  Preserved autoregulation of coronary flow after off-pump coronary artery bypass grafting: retrospective assessment of intraoperative transit time flowmetry with and without intra-aortic balloon counterpulsation.

Authors:  Hiroyuki Nakajima; Atsushi Iguchi; Mimiko Tabata; Masaru Kambe; Masahiro Ikeda; Kazuhiko Uwabe; Toshihisa Asakura; Hiroshi Niinami
Journal:  J Cardiothorac Surg       Date:  2016-11-28       Impact factor: 1.637

3.  Contemporary outcomes of cardiac surgery patients supported by the intra-aortic balloon pump.

Authors:  Roberto Lorusso; Samuel Heuts; Federica Jiritano; Roberto Scrofani; Carlo Antona; Guglielmo Actis Dato; Paolo Centofanti; Sandro Ferrarese; Matteo Matteucci; Antonio Miceli; Mattia Glauber; Enrico Vizzardi; Sandro Sponga; Igor Vendramin; Andrea Garatti; Carlo de Vincentis; Michele De Bonis; Silvia Ajello; Giovanni Troise; Margherita Dalla Tomba; Filiberto Serraino
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-06-15

4.  Intraoperative Assessment of Coronary Resistances: A New Quality Marker and Potential Tool to Predict Early Graft Failure after Coronary Artery Bypass Grafting?

Authors:  Antonino Salvatore Rubino; Fabrizio Ceresa; Liborio Mammana; Giuseppe Vite; Gianluca Cullurà; Augusto Palermo; Aurora Leonardi; Bruna Filomena De Donno; Francesco Patanè
Journal:  J Cardiovasc Dev Dis       Date:  2021-11-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.