Predictive factors of success following radio-frequency stylet (RFS) ablation of incompetent perforating veins (IPV).

Anil P Hingorani1, Enrico Ascher, Natalie Marks, Alexander Shiferson, Nirav Patel, Kapil Gopal, Theresa Jacob.   

Abstract

OBJECTIVE: To evaluate potential predictive factors associated with success or failure of incompetent perforating veins (IPVs) treated with radio-frequency stylet (RFS).
METHODS: Over the last 12 months in this observational study, 38 consecutive patients with various degrees of venous insufficiency and IPVs underwent 48 office-based radio-frequency ablation procedures (1 - C 3; 7 - C 4; 10 - C 5; 30 - C 6) in 44 limbs. There were 21 females and 17 males with a mean age of 67 +/- 17 years (38-93 years) who had a total of 93 IPVs (40 calf; 53 ankle). Eighteen patients (47%) had ipsilateral great saphenous vein (GSV) radio-frequency closures performed prior to current procedure. The venous flow pattern was classified by spectral waveform analysis as "normal" (spontaneous with respiratory phasicity) in 33 patients and "pulsatile" (with bidirectional cardiac phasicity) in five patients. Follow-up duplex scans were performed from 3 to 7 days postprocedure. Statistical analyses were performed for determining correlation between the various factors such as, age, pulsatile flow, CEAP class, prior GSV ablation, vein diameter, reflux, and patency.
RESULTS: The mean number of ablated IPVs was 1.94 +/- 0.38 ranging from 1-3. Immediate success rate was 88% (82 cases, 32 patients). IPVs had a duplex measured mean diameter of 3.8 +/- 1.1 mm (2-6.6 mm). Eleven IPVs remained patent in six patients. There was no significant difference between the patent and the obliterated IPV groups concerning age (P = 0.75), prior GSV ablation (P = .19), IPV diameter (P = .08) and CEAP classification. Conversely, four of the five procedures (80%) performed in patients with "pulsatile" venous flow failed, while only two of the remaining 43 procedures (4.7%) in patients with "normal" venous flow failed (P < .001).
CONCLUSION: These data show that a pulsatile venous flow pattern is a significant predictor of failure following RFS for IPVs.

Entities:  

Mesh:

Year:  2009        PMID: 19576715     DOI: 10.1016/j.jvs.2009.04.046

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  1 in total

Review 1.  Minimally invasive treatments for perforator vein insufficiency.

Authors:  Gokhan Kuyumcu; Gloria Maria Salazar; Anand M Prabhakar; Suvranu Ganguli
Journal:  Cardiovasc Diagn Ther       Date:  2016-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.