Literature DB >> 19576589

Evaluation of various liquid chromatography-quadrupole-linear ion trap-mass spectrometry operation modes applied to the analysis of organic pollutants in wastewaters.

María Jesús Martínez Bueno1, Ana Agüera, María Dolores Hernando, María José Gómez, Amadeo R Fernández-Alba.   

Abstract

The LC-MS/MS analysis of a group of 14 organic pollutants in wastewater--including pharmaceuticals (analgesics/anti-inflammatories, lipid regulators and diuretics), pesticides (diuron) and disinfectants (chlorophene)--has been carried out using a hybrid triple quadrupole-linear ion trap-mass spectrometer (QqLIT). In order to take advantage of the capabilities of the QqLIT system, two methods have been developed and compared, based on the application of different operation modes. One of them uses selected reaction monitoring (SRM), which is the standard mode for quantitative LC-MS/MS analysis. The other is based on the use of an information dependent acquisition scan function (IDA), which allows the combination of a SRM acting as the survey scan and an enhanced product ion scan (EPI) as dependent scan within the same analysis. Performance of both methods was compared, especially in terms of their limits of detection and identification capability. The advantages and limitations of both techniques are discussed. Finally, the two methodologies developed were applied to real samples for evaluation of effluent wastewater in a treatment plant on the south-eastern Mediterranean coast of Spain. The presence of most of the target compounds was detected at mean concentrations ranging from 50 ng/L (mefenamic acid) to 3373 ng/L (hydrochlorothiazide).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19576589     DOI: 10.1016/j.chroma.2009.06.047

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Analytical improvements of hybrid LC-MS/MS techniques for the efficient evaluation of emerging contaminants in river waters: a case study of the Henares River (Madrid, Spain).

Authors:  Andrés Pérez-Parada; María del Mar Gómez-Ramos; María Jesús Martínez Bueno; Samanta Uclés; Ana Uclés; Amadeo R Fernández-Alba
Journal:  Environ Sci Pollut Res Int       Date:  2011-08-07       Impact factor: 4.223

2.  Screening and quantification of emerging contaminants in Periyar River, Kerala (India) by using high-resolution mass spectrometry (LC-Q-ToF-MS).

Authors:  Nejumal K Khalid; Dineep Devadasan; Usha K Aravind; Charuvila T Aravindakumar
Journal:  Environ Monit Assess       Date:  2018-05-31       Impact factor: 2.513

Review 3.  New trends in the analytical determination of emerging contaminants and their transformation products in environmental waters.

Authors:  Ana Agüera; María Jesús Martínez Bueno; Amadeo R Fernández-Alba
Journal:  Environ Sci Pollut Res Int       Date:  2013-03-01       Impact factor: 4.223

4.  Pilot monitoring study of ibuprofen in surface waters of north of Portugal.

Authors:  Paula Paíga; Lúcia H M L M Santos; Célia G Amorim; Alberto N Araújo; M Conceição B S M Montenegro; Angelina Pena; Cristina Delerue-Matos
Journal:  Environ Sci Pollut Res Int       Date:  2012-08-30       Impact factor: 4.223

5.  Binding of bezafibrate to human serum albumin: insight into the non-covalent interaction of an emerging contaminant with biomacromolecules.

Authors:  Yajie Qian; Xuefei Zhou; Jiabin Chen; Yalei Zhang
Journal:  Molecules       Date:  2012-06-04       Impact factor: 4.411

6.  An optimized SPE-LC-MS/MS method for antibiotics residue analysis in ground, surface and treated water samples by response surface methodology- central composite design.

Authors:  Roya Mirzaei; Masoud Yunesian; Simin Nasseri; Mitra Gholami; Esfandiyar Jalilzadeh; Shahram Shoeibi; Hooshang Shafieyan Bidshahi; Alireza Mesdaghinia
Journal:  J Environ Health Sci Eng       Date:  2017-10-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.