Literature DB >> 19576454

Simple and rapid voltammetric determination of morphine at electrochemically pretreated glassy carbon electrodes.

Fei Li1, Jixia Song, Dongmei Gao, Qixian Zhang, Dongxue Han, Li Niu.   

Abstract

A simple and rapid method for morphine detection has been described based on electrochemical pretreatment of glassy carbon electrode (GCE) which was treated by anodic oxidation at 1.75 V, following potential cycling in the potential range from 0 V to 1.0 V vs. Ag|AgCl reference electrode. The sensitivity for morphine detection was improved greatly and the detection limit was 0.2 microM. The reproducibility of the voltammetric measurements was usually less than 3% RSD for six replicate measurements. Moreover, this method could readily discriminate morphine from codeine. And an electrochemical detection of morphine in spiked urine sample was succeeded with satisfactory results.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19576454     DOI: 10.1016/j.talanta.2009.05.011

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Silane modified magnetic nanoparticles as a novel adsorbent for determination of morphine at trace levels in human hair samples by high-performance liquid chromatography with diode array detection.

Authors:  Ali Boojaria; Mahboubeh Masrournia; Hamideh Ghorbani; Abdolhossein Ebrahimitalab; Mina Miandarhoie
Journal:  Forensic Sci Med Pathol       Date:  2015-08-30       Impact factor: 2.007

2.  Recent advances in immunosensor for narcotic drug detection.

Authors:  Sonu Gandhi; Pankaj Suman; Ashok Kumar; Prince Sharma; Neena Capalash; C Raman Suri
Journal:  Bioimpacts       Date:  2015-12-28

3.  Fast Electrocatalytic Determination of Methimazole at an Activated Glassy Carbon Electrode.

Authors:  Fahimeh Jalali; Zahra Hatami
Journal:  Iran J Pharm Res       Date:  2016       Impact factor: 1.696

4.  Simultaneous Detection of Morphine and Codeine in the Presence of Ascorbic Acid and Uric Acid and in Human Plasma at Nafion Single-Walled Carbon Nanotube Thin-Film Electrode.

Authors:  Niklas Wester; Elsi Mynttinen; Jarkko Etula; Tuomas Lilius; Eija Kalso; Esko I Kauppinen; Tomi Laurila; Jari Koskinen
Journal:  ACS Omega       Date:  2019-10-16

5.  Rapid and sensitive determination of doxorubicin in human whole blood by vertically-ordered mesoporous silica film modified electrochemically pretreated glassy carbon electrodes.

Authors:  Meifang Wang; Jing Lin; Jiawei Gong; Mingchen Ma; Hongliang Tang; Jiyang Liu; Fei Yan
Journal:  RSC Adv       Date:  2021-03-01       Impact factor: 3.361

6.  Simultaneous determination of methadone and morphine at a modified electrode with 3D β-MnO2 nanoflowers: application for pharmaceutical sample analysis.

Authors:  Sedigheh Akbari; Shohreh Jahani; Mohammad Mehdi Foroughi; Hadi Hassani Nadiki
Journal:  RSC Adv       Date:  2020-10-19       Impact factor: 4.036

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.