Literature DB >> 19576417

Ionic liquids as mobile phase additives in high-performance liquid chromatography with electrochemical detection: application to the determination of heterocyclic aromatic amines in meat-based infant foods.

Aurora Martín-Calero1, Verónica Pino, Juan H Ayala, Venerando González, Ana M Afonso.   

Abstract

The beneficial effects of several ionic liquids (ILs) as mobile phase additives in high-performance liquid chromatography with electrochemical detection for the determination of six heterocyclic aromatic amines (HAs) have been evaluated for first-time. The studied ionic liquids were 1-butyl-3-methylimidazolium tetrafluoroborate (BMIm-BF(4)), 1-hexyl-3-methylimidazolium tetrafluoroborate (HMIm-BF(4)) and 1-methyl-3-octylimidazolium tetrafluoroborate (MOIm-BF(4)). Several chromatographic parameters have been evaluated in the presence or absence of ILs, or using ammonium acetate as the most common mobile phase additive, with three different C18 stationary phases. The effect of the acetonitrile content was also addressed. In general, best resolution, lower peak-widths (up to 72.1% lower) and lower retention factors are obtained when using ILs rather than ammonium acetate as mobile phase additives. The main improvement was obtained in the baseline noise, being 360% less noisy for BMIm-BF(4), 310% for HMIm-BF(4), and 227% for MOIm-BF(4), when compared to ammonium acetate at +1000 mV. Different chromatographic methods using the best conditions for each IL were also evaluated and compared. Finally, the best chromatographic conditions using 1mM of BMIm-BF(4) as mobile phase additive, the Nova-Pak C18 column, 19% (v/v) of acetonitrile content in the mobile phase, and +1000 mV in the ECD, have been applied for the chromatographic analysis of six HAs contained in meat-based infant foods. The whole extraction method of meat-based infant foods using focused microwave-assisted extraction and solid-phase extraction has also been optimized. Extraction efficiencies up to 89% and detection limits ranged between 9.30 and 0.165 ng g(-1) have been obtained under optimized conditions.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19576417     DOI: 10.1016/j.talanta.2009.04.032

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Fluorescence characteristics of bisphenol A in room temperature ionic liquids.

Authors:  Huili Wang; Yujie Zou; Changli Li; Wenwei Wang; Minghua Zhang; Randy A Dahlgren; Xuedong Wang
Journal:  J Fluoresc       Date:  2013-07-11       Impact factor: 2.217

2.  Effect of ionic liquid on the determination of aromatic amines as contaminants in hair dyes by liquid chromatography coupled to electrochemical detection.

Authors:  Thiago Mescoloto Lizier; Maria Valnice Boldrin Zanoni
Journal:  Molecules       Date:  2012-07-02       Impact factor: 4.411

Review 3.  Recent applications of ionic liquids in separation technology.

Authors:  Dandan Han; Kyung Ho Row
Journal:  Molecules       Date:  2010-04-05       Impact factor: 4.411

Review 4.  Heterocyclic Aromatic Amines in Meat: Formation, Isolation, Risk Assessment, and Inhibitory Effect of Plant Extracts.

Authors:  Hafiz Rehan Nadeem; Saeed Akhtar; Tariq Ismail; Piero Sestili; Jose Manuel Lorenzo; Muhammad Modassar Ali Nawaz Ranjha; Leonie Jooste; Christophe Hano; Rana Muhammad Aadil
Journal:  Foods       Date:  2021-06-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.