Literature DB >> 19576408

Gait and motion analysis of the lower extremity after total hip arthroplasty: what the orthopedic surgeon should know.

Mario Lamontagne1, Mélanie L Beaulieu, Daniel Varin, Paul E Beaulé.   

Abstract

This article presents critical issues related to the interpretation of biomechanical findings of the hip joint for patients having undergone hip arthroplasty. The use of a gait, or biomechanical, analysis provides objective evidence of the efficiency of the treatments or the effectiveness of hip replacement approaches. Based on our biomechanical analysis, patients who have undergone total hip arthroplasty use a stair ascent and descent strategy allowing them to significantly reduce loading at the prosthetic hip joint. Since hip joint reaction forces are highly dependent on muscle activation, the THA group have adopted a neuromuscular control strategy that is enabling them to reduce loading on the prosthetic hip joint. It could also be a joint loading pattern that stems from a muscular deficiency emerging either from several years of loading avoidance on the affected hip joint or from the surgical procedure. Therefore, a biomechanical analysis of human motion is a valuable tool for the orthopedic surgeon to objectively quantify joint motion and the forces producing this motion.

Entities:  

Mesh:

Year:  2009        PMID: 19576408     DOI: 10.1016/j.ocl.2009.02.001

Source DB:  PubMed          Journal:  Orthop Clin North Am        ISSN: 0030-5898            Impact factor:   2.472


  3 in total

1.  Does surgical approach influence mid- to long-term patient-reported outcomes after primary total hip replacement? A comparison of the 3 main surgical approaches.

Authors:  Romain Galmiche; Stéphane Poitras; Johanna Dobransky; Paul R Kim; Robert J Feibel; Wade Gofton; Hesham Abdelbary; Paul E Beaulé
Journal:  Can J Surg       Date:  2020-04-17       Impact factor: 2.089

2.  Different reliability of instrumented gait analysis between patients with unilateral hip osteoarthritis, unilateral hip prosthesis and healthy controls.

Authors:  Roland Zügner; Roy Tranberg; Vera Lisovskaja; Johan Kärrholm
Journal:  BMC Musculoskelet Disord       Date:  2018-07-18       Impact factor: 2.362

3.  Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty.

Authors:  Roland Zügner; Roy Tranberg; John Timperley; Diana Hodgins; Maziar Mohaddes; Johan Kärrholm
Journal:  BMC Musculoskelet Disord       Date:  2019-02-06       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.