Literature DB >> 19576389

Portable microfluidic system for determination of urinary creatinine.

Temsiri Songjaroen1, Thitima Maturos, Aussawapong Sappat, Adisorn Tuantranont, Wanida Laiwattanapaisal.   

Abstract

A simple, low cost and portable microfluidic system based on a two-point alkaline picrate kinetic reaction has been developed for the determination of urinary creatinine. The creatinine reacts with picric acid under alkaline conditions, forming an orange-red colour, which is monitored on PDMS microchip using a portable miniature fibre optic spectrometer at 510 nm. A linear range was displayed from 0 to 40 mg L(-1) creatinine (r2 = 0.997) with a detection limit of 3.3 mg L(-1) (S/N = 3). On-chip absorbance signals are reproducible, with relative standard deviations (RSDs) of 7.1%, when evaluated with 20 mg L(-1) creatinine (n = 10). The standard curves in which the intra-run CVs (4.7-6.8%) and inter-run CVs (7.9%) obtained were performed on three different days and exhibited good reproducibility. The method was highly correlated with the conventional spectrophotometric method when real urine samples were evaluated (r2 = 0.948; n = 15).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19576389     DOI: 10.1016/j.aca.2009.05.014

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  On-chip immunoassay for determination of urinary albumin.

Authors:  Wanida Laiwattanapaisal; Temsiri Songjaroen; Thitima Maturos; Tanom Lomas; Assawapong Sappat; Adisorn Tuantranont
Journal:  Sensors (Basel)       Date:  2009-12-10       Impact factor: 3.576

Review 2.  Applications of Microfluidic Devices for Urology.

Authors:  Se Jik Han; Hun-Kuk Park; Kyung Sook Kim
Journal:  Int Neurourol J       Date:  2017-04-21       Impact factor: 2.835

3.  Disposable Nonenzymatic Uric Acid and Creatinine Sensors Using μPAD Coupled with Screen-Printed Reduced Graphene Oxide-Gold Nanocomposites.

Authors:  Kamolwich Income; Nalin Ratnarathorn; Napassawan Khamchaiyo; Chanut Srisuvo; Leela Ruckthong; Wijitar Dungchai
Journal:  Int J Anal Chem       Date:  2019-02-03       Impact factor: 1.885

4.  Gradient Waveguide Thickness Guided-Mode Resonance Biosensor.

Authors:  Jia-Ming Yang; Nien-Zu Yang; Cheng-Hao Chen; Cheng-Sheng Huang
Journal:  Sensors (Basel)       Date:  2021-01-07       Impact factor: 3.576

Review 5.  Simplifying the complex: accessible microfluidic solutions for contemporary processes within in vitro diagnostics.

Authors:  Nathan K Khosla; Jake M Lesinski; Monika Colombo; Léonard Bezinge; Andrew J deMello; Daniel A Richards
Journal:  Lab Chip       Date:  2022-09-13       Impact factor: 7.517

6.  Determination of Albumin, Glucose, and Creatinine Employing a Single Sequential Injection Lab-at-Valve with Mono-Segmented Flow System Enabling In-Line Dilution, In-Line Single-Standard Calibration, and In-Line Standard Addition.

Authors:  Kanokwan Kiwfo; Wasin Wongwilai; Tadao Sakai; Norio Teshima; Kate Grudpan
Journal:  Molecules       Date:  2020-04-04       Impact factor: 4.411

  6 in total