Literature DB >> 19575190

Development of a multichannel flow-through chemiluminescence microarray chip for parallel calibration and detection of pathogenic bacteria.

Xaver Y Z Karsunke1, Reinhard Niessner, Michael Seidel.   

Abstract

Pathogen detection is important for health and safety reasons. Several outbreaks all over the world have shown the need for rapid, qualitative, quantitative, and, particularly, multianalyte detection systems. Hence, a multichannel flow-through chemiluminescence microarray chip for parallel detection of pathogenic bacteria was developed. The disposable chip made of acrylonitrile-butadiene-styrene (ABS) copolymer was devised as a support for a multiplexed sandwich immunoassay. Calibration and measurement was possible in one experiment, because the developed chip contains six parallel flow-through microchannels. Polyclonal antibodies against the pathogenic bacteria Escherichia coli O157:H7, Salmonella typhimurium, and Legionella pneumophila were immobilized on the chip by microcontact printing in order to use them as specific receptors. Detection of the captured bacteria was carried out by use of specific detection antibodies labelled with biotin and horseradish peroxidase (HRP)-streptavidine conjugates. The enzyme HRP generates chemiluminescence after adding luminol and hydrogen peroxide. This signal was observed by use of a sensitive CCD camera. The limits of detection are 1.8 x 10(4) cells mL(-1) for E. coli O157:H7, 7.9 x 10(4) cells mL(-1) for L. pneumophila, and 2.0 x 10(7) cells mL(-1) for S. typhimurium. The overall assay time for measurement and calibration is 18 min, enabling very fast analysis.

Entities:  

Mesh:

Year:  2009        PMID: 19575190     DOI: 10.1007/s00216-009-2905-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

Review 1.  Microarray Strategies for Exploring Bacterial Surface Glycans and Their Interactions With Glycan-Binding Proteins.

Authors:  María Asunción Campanero-Rhodes; Angelina Sa Palma; Margarita Menéndez; Dolores Solís
Journal:  Front Microbiol       Date:  2020-01-10       Impact factor: 5.640

Review 2.  Advances in Optical Detection of Human-Associated Pathogenic Bacteria.

Authors:  Andrea Locke; Sean Fitzgerald; Anita Mahadevan-Jansen
Journal:  Molecules       Date:  2020-11-11       Impact factor: 4.411

3.  Microfluidic biosensor array with integrated poly(2,7-carbazole)/fullerene-based photodiodes for rapid multiplexed detection of pathogens.

Authors:  Nuno Miguel Matos Pires; Tao Dong
Journal:  Sensors (Basel)       Date:  2013-11-25       Impact factor: 3.576

Review 4.  Multiplex bioanalytical methods for food and environmental monitoring.

Authors:  Sabina Rebe Raz; Willem Haasnoot
Journal:  Trends Analyt Chem       Date:  2011-07-29       Impact factor: 12.296

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.