Literature DB >> 19574144

An ultrasonic imaging speckle-suppression and contrast-enhancement technique by means of frequency compounding and coded excitation.

Jose R Sanchez1, Michael L Oelze.   

Abstract

A method for improving the contrast resolution of B-mode images is proposed by combining the speckle-reduction technique of frequency compounding (FC) and the coded excitation and pulse-compression technique called resolution enhancement compression (REC). FC suppresses speckle but at the expense of a reduction in axial resolution. Using REC, the axial resolution and bandwidth of the imaging system was doubled. Therefore, by combining REC with FC (REC-FC), the tradeoff between axial resolution and contrast enhancement was extended significantly. Simulations and experimental measurements were conducted with a single-element transducer (f/2.66) having a center frequency of 2.25 MHz and a -3-dB bandwidth of 50%. Simulations and measurements of hyperechoic (+6 dB) tissue-mimicking targets were imaged. Four FC cases were evaluated: full-, half-, third-, and fourth-width of the true impulse response bandwidth. The image quality metrics used to compare REC-FC to conventional pulsing (CP) and CP-FC were contrast-to-noise ratio (CNR), speckle signal-to-noise ratio, histogram pixel intensity, and lesion signal-to-noise ratio. Increases in CNR of 121%, 231%, 302%, and 391% were obtained in experiments when comparing REC-FC for the full-, half-, third-, and fourth-width cases to CP. Furthermore, smaller increases in CNR of 112%, 233%, and 309% were obtained in experiments when comparing CP-FC for the half-, third-, and fourth-width cases to CP. Improved lesion detectability was observed by using REC-FC.

Entities:  

Mesh:

Year:  2009        PMID: 19574144     DOI: 10.1109/TUFFC.2009.1189

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Improved scatterer property estimates from ultrasound backscatter using gate-edge correction and a pseudo-Welch technique.

Authors:  Goutam Ghoshal; Michael L Oelze
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-12       Impact factor: 2.725

2.  Barker-coded excitation in ophthalmological ultrasound imaging.

Authors:  Sheng Zhou; Xiao-Chun Wang; Jun Yang; Jian-Jun Ji; Yan-Qun Wang
Journal:  Int J Clin Exp Med       Date:  2014-09-15

3.  Coded Spectral Doppler Imaging: From Simulation to Real-Time Processing.

Authors:  Alessandro Ramalli; Enrico Boni; Alessandro Dallai; Francesco Guidi; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-26       Impact factor: 2.725

4.  Ultrasound despeckling for contrast enhancement.

Authors:  Peter C Tay; Christopher D Garson; Scott T Acton; John A Hossack
Journal:  IEEE Trans Image Process       Date:  2010-03-11       Impact factor: 10.856

5.  Frequency-Dependent Spatial Coherence in Conventional and Chirp Transmissions.

Authors:  James Long; Nick Bottenus; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-04-26       Impact factor: 2.725

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.