Literature DB >> 19574133

Real-time volume imaging using a crossed electrode array.

Christine E M Démoré1, Andrew W Joyce, Kieran Wall, Geoffrey R Lockwood.   

Abstract

This paper describes a unique crossed electrode array for real-time volume ultrasound imaging. By placing orthogonal linear array electrode patterns on the opposite sides of a hemispherically shaped composite transducer substrate, a 2-D array can be fabricated using a small fraction of the elements required for a traditional 2-D array. The performance of the array is investigated using a computer simulation of the radiation pattern. We show that by using a 288-element crossed electrode pattern it is possible to collect large field of view volume images (60 degrees x 60 degrees sector) at real-time frame rates (>20 volume images/s), with image contrast and resolution comparable to what can be obtained using a conventional 128-element linear phased array.

Mesh:

Year:  2009        PMID: 19574133     DOI: 10.1109/TUFFC.2009.1167

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  8 in total

1.  Beamforming of sound from two-dimensional arrays using spatial matched filters.

Authors:  Jesse T Yen
Journal:  J Acoust Soc Am       Date:  2013-11       Impact factor: 1.840

2.  Comparison of virtual source synthetic aperture beamforming with an element-based model.

Authors:  Nick Bottenus
Journal:  J Acoust Soc Am       Date:  2018-05       Impact factor: 1.840

3.  Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging.

Authors:  Gokce Gurun; Coskun Tekes; Jaime Zahorian; Toby Xu; Sarp Satir; Mustafa Karaman; Jennifer Hasler; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-02       Impact factor: 2.725

4.  A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate.

Authors:  Jean L Sanders; Ali Onder Biliroglu; Xun Wu; Oluwafemi J Adelegan; Feysel Yalcin Yamaner; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

5.  A novel encoded excitation scheme in a phased array for the improving data acquisition rate.

Authors:  César Gutiérrez-Fernández; Ana Jiménez; Carlos Julián Martín-Arguedas; Jesús Ureña; Álvaro Hernández
Journal:  Sensors (Basel)       Date:  2013-12-31       Impact factor: 3.576

Review 6.  A Review on Real-Time 3D Ultrasound Imaging Technology.

Authors:  Qinghua Huang; Zhaozheng Zeng
Journal:  Biomed Res Int       Date:  2017-03-26       Impact factor: 3.411

7.  Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model.

Authors:  Ibrahim Ben Daya; Albert I H Chen; Mohammad Javad Shafiee; Alexander Wong; John T W Yeow
Journal:  PLoS One       Date:  2015-12-11       Impact factor: 3.240

8.  The Design and Analysis of Split Row-Column Addressing Array for 2-D Transducer.

Authors:  Xu Li; Yanping Jia; Mingyue Ding; Ming Yuchi
Journal:  Sensors (Basel)       Date:  2016-09-27       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.