Literature DB >> 19573752

Dilatation of aortic grafts over time: what to expect and when to be concerned.

Torben V Schroeder1, Nikolaj Eldrup, Sven Just, Marc Hansen, Bo Nyhuus, Henrik Sillesen.   

Abstract

Dilatation of aortic prosthetic grafts is commonly reported, but most reports are anecdotal, with little objective data in the literature. We performed a prospective trial of 303 patients who underwent prosthetic graft repair for aortic aneurysm or occlusive disease, randomizing patients between insertion of a woven polyester or expanded polytetrafluoroethylene (ePTFE) graft. Patients were followed with computed tomography and ultrasonography for up to 5 years in order to assess the frequency and magnitude of postoperative dilatation. Graft dilatation was documented in patients with polyester grafts at 12 months. Thereafter and up to 60 months, polyester grafts did not dilate further. After 5 years, polyester prostheses had dilated by 25% and ePTFE by 12.5%, as determined by computed tomography imaging. These observations suggest that dilatation of prosthetic grafts is more frequent with knitted polyester grafts compared with ePTFE. Dilatation occurs within the first year after implantation and can be, in part, explained by a discrepancy between the initial nominal graft diameter and its diameter after clamp release, probably due to an in vivo adaptation of the textile structure. Interestingly, graft dilatation did not appear to be associated with an increased frequency of graft-related complications.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19573752     DOI: 10.1053/j.semvascsurg.2009.04.002

Source DB:  PubMed          Journal:  Semin Vasc Surg        ISSN: 0895-7967            Impact factor:   1.000


  3 in total

1.  Relationship between the distal migration and length of the distal landing zone after endovascular aneurysm repair (EVAR).

Authors:  Tsutomu Ihara; Kimihiro Komori; Hiroshi Banno; Akio Kodama; Kiyohito Yamamoto; Masayuki Sugimoto
Journal:  Surg Today       Date:  2014-12-25       Impact factor: 2.549

2.  Hybrid repair versus conventional open repair for thoracic aortic arch aneurysms.

Authors:  Ala Elhelali; Niamh Hynes; Declan Devane; Sherif Sultan; Edel P Kavanagh; Liam Morris; Dave Veerasingam; Fionnuala Jordan
Journal:  Cochrane Database Syst Rev       Date:  2021-06-04

3.  Late Disruption of a Polyethylene Terephthalate Aortic Graft 30 Years after Initial Graft Placement.

Authors:  Akihito Matsushita; Yu Tsunoda; Takashi Hattori; Wahei Mihara
Journal:  EJVES Short Rep       Date:  2017-12-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.