Literature DB >> 19572170

Endovascular treatment of autogenous radiocephalic fistulas with the "eighth note" deformity for hemodialysis.

Mei-Jui Weng1, Matt Chiung-Yu Chen, Wen-Che Chi, Yi-Chun Liu, Ko-Fen Chien, Huei-Lung Liang, Huay-Ben Pan.   

Abstract

The purpose of this paper is to describe a unique "eighth note" deformity of the autogenous radiocephalic fistula for hemodialysis and to retrospectively evaluate the efficacy and safety of its endovascular treatment. Over 3 years, a total of 808 patients and 558 autogenous radiocephalic fistulas were treated for vascular access dysfunction or thrombosis. These included 14 fistulas in 14 patients (9 men, 5 women; mean age, 58.2 +/- 2.8 years; range 27-79 years) whose fistulograms before treatment resembled a musical note, the eighth note. Endovascular treatment sought to remodel the deformed vascular access to a classic radiocephalic fistula and increase the number of cannulation sites available for hemodialysis. The technical and clinical success rates were each 92.8% (13/14). Fistula remodeling was successful in 13 patients. The postintervention primary patency was 100% at 90 days, 91.7 +/- 0.8% at 120 days, 78.6 +/- 13.9% at 180 days, 62.9 +/- 17.9% at 360 days, 31.4 +/- 24.0% at 540 days, and 0% at 720 days. The postintervention secondary patency was 100% at 90 days, 100% at 120 days, 100% at 180 days, 85.7 +/- 13.2% at 360 days, and 85.7 +/- 13.2% at 720 days. No major complications were noted. Minor complications were found in 71.4% of patients, all of which resolved spontaneously. In conclusion, endovascular treatment of fistulas with the eighth note deformity can effectively increase the number of available cannulation sites, facilitate fistula maturation, and facilitate thromboaspiration after fistula thrombosis.

Entities:  

Mesh:

Year:  2009        PMID: 19572170     DOI: 10.1007/s00270-009-9639-y

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

1.  Quantification of the severity of outflow stenosis of hemodialysis fistulas with a pulse- and thrill-based scoring system.

Authors:  Matt Chiung-Yu Chen; Mei-Jui Weng; Bai-Chun Chang; Hsiu-Ching Lai; Misoso Yi-Wen Wu; Chia-Yun Fu; Yi-Chun Liu; Wen-Che Chi
Journal:  BMC Nephrol       Date:  2020-07-25       Impact factor: 2.388

2.  Measuring the palpable pulsatility length as a physical examination test in defining the severity of inflow stenosis for hemodialysis fistulas.

Authors:  Matt Chiung-Yu Chen; Mei-Jui Weng; Misoso Yi-Wen Wu; Yi-Chun Liu; Wen-Che Chi
Journal:  BMC Nephrol       Date:  2019-09-13       Impact factor: 2.388

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.