High performance liquid chromatography-tandem mass spectrometry for the analysis of 10 pesticides in water: a comparison between membrane-assisted solvent extraction and solid phase extraction.

Manuela van Pinxteren1, Coretta Bauer, Peter Popp.   

Abstract

This work describes the application of two sample preparation methods: membrane-assisted solvent extraction (MASE) and solid phase extraction (SPE) in combination with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) for the determination of 10 pesticides in surface and ground water. Optimal extraction conditions for MASE were 60 min extraction time at 30 degrees C with a solvent volume of 100 microL toluene. 5 microL of the toluene extract were directly injected in the HPLC-MS-MS system. Concerning SPE, two materials were tested and C18 was superior to Oasis HLB. Complete desorption was ensured by desorbing the SPE (C18) cartridge with 3 mL of an acetonitrile/methanol mixture (1:1). After evaporation, the extract was injected in the analytical system. Analyte breakthrough was not found for the investigated compounds. For both methods, high extraction yields were achieved, in detail 71% (metalaxyl) till 105% (linuron) for MASE and 52% (ethiofencarb) till 77% (prometryne) for SPE (C18). Detection limits were in the low ng/L range for both methods and precision, expressed as the relative standard deviation (RSD) of the peak areas was below 13%. Five real water samples were analyzed applying both extraction methods. The results were in good agreement and standard addition proved that no matrix effects (such as ion suppression) occurred. In this comparison SPE has the potential of larger sensitivity whereas faster analysis and slightly better recoveries were achieved with MASE. MASE shows potential to be a promising alternative to the conventional off-line SPE concerning low to medium polar compounds.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19570541     DOI: 10.1016/j.chroma.2009.06.027

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  An environmentally friendly method for the determination of triazine herbicides in estuarine seawater samples by dispersive liquid-liquid microextraction.

Authors:  N Rodríguez-González; E Beceiro-González; M J González-Castro; S Muniategui-Lorenzo
Journal:  Environ Sci Pollut Res Int       Date:  2014-08-07       Impact factor: 4.223

2.  Part I: temporal and spatial distribution of multiclass pesticide residues in lake waters of Northern Greece: application of an optimized SPE-UPLC-MS/MS pretreatment and analytical method.

Authors:  Eleni-Chrysoula Kalogridi; Christophoros Christophoridis; Erasmia Bizani; Garyfallia Drimaropoulou; Konstantinos Fytianos
Journal:  Environ Sci Pollut Res Int       Date:  2014-04-04       Impact factor: 4.223

Review 3.  Optimising factors affecting solid phase extraction performances of molecular imprinted polymer as recent sample preparation technique.

Authors:  Gabriella Josephine Maranata; Natasha Octavianti Surya; Aliya Nur Hasanah
Journal:  Heliyon       Date:  2021-01-28

4.  Application of a developed method for the extraction of triazines in surface waters and storage prior to analysis to seawaters of Galicia (northwest Spain).

Authors:  Noelia Rodríguez-González; Elisa Beceiro-González; María José González-Castro; Soledad Muniategui-Lorenzo
Journal:  ScientificWorldJournal       Date:  2013-10-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.