Literature DB >> 19568324

A low-cost, universal, and cumulative gating circuit for small and large animal clinical imaging.

Sylvain Gioux1, John V Frangioni.   

Abstract

Image-assisted diagnosis and therapy is becoming more commonplace in medicine. However, most imaging techniques suffer from voluntary or involuntary motion artifacts, especially cardiac and respiratory motions, which degrade image quality. Current software solutions either induce computational overhead or reject out-of-focus images after acquisition. In this study we demonstrate a hardware-only gating circuit that accepts multiple, pseudo-periodic signals and produces a single TTL (0-5 V) imaging window of accurate phase and period. The electronic circuit Gerber files described in this article and the list of components are available online at www.frangionilab.org.

Entities:  

Year:  2008        PMID: 19568324      PMCID: PMC2703438          DOI: 10.1901/jaba.2008.6848-6481I

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  6 in total

1.  The principles of software QRS detection.

Authors:  Bert-Uwe Köhler; Carsten Hennig; Reinhold Orglmeister
Journal:  IEEE Eng Med Biol Mag       Date:  2002 Jan-Feb

Review 2.  Fluorescence-enhanced, near infrared diagnostic imaging with contrast agents.

Authors:  Eva M Sevick-Muraca; Jessica P Houston; Michael Gurfinkel
Journal:  Curr Opin Chem Biol       Date:  2002-10       Impact factor: 8.822

Review 3.  Fluorescence imaging with near-infrared light: new technological advances that enable in vivo molecular imaging.

Authors:  Vasilis Ntziachristos; Christoph Bremer; Ralph Weissleder
Journal:  Eur Radiol       Date:  2002-07-19       Impact factor: 5.315

4.  Modulated imaging: quantitative analysis and tomography of turbid media in the spatial-frequency domain.

Authors:  David J Cuccia; Frederic Bevilacqua; Anthony J Durkin; Bruce J Tromberg
Journal:  Opt Lett       Date:  2005-06-01       Impact factor: 3.776

5.  Real-time intraoperative ureteral guidance using invisible near-infrared fluorescence.

Authors:  Eiichi Tanaka; Shunsuke Ohnishi; Rita G Laurence; Hak Soo Choi; Valerie Humblet; John V Frangioni
Journal:  J Urol       Date:  2007-09-17       Impact factor: 7.450

6.  Image-guided quantification of cardioplegia delivery during cardiac surgery.

Authors:  Edward G Soltesz; Rita G Laurence; Alec M De Grand; Lawrence H Cohn; Tomislav Mihaljevic; John V Frangioni
Journal:  Heart Surg Forum       Date:  2007       Impact factor: 0.676

  6 in total
  1 in total

1.  Three-dimensional surface profile intensity correction for spatially modulated imaging.

Authors:  Sylvain Gioux; Amaan Mazhar; David J Cuccia; Anthony J Durkin; Bruce J Tromberg; John V Frangioni
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.