Literature DB >> 19568032

Total body water measurements in adolescent athletes: a comparison of six field methods with deuterium dilution.

Ana L Quiterio1, Analiza M Silva, Cláudia S Minderico, Elvis A Carnero, David A Fields, Luis B Sardinha.   

Abstract

-Assessing hydration, that is, total body water (TBW) in adolescent athletes should be part of a comprehensive training program. However, there are no specific methods to assess TBW in young athletes. Moreover, the use of traditional techniques developed in healthy youths, based on a 2-compartment model, may yield inaccurate TBW estimates in young athletes. Therefore, the purpose of this study was to assess the accuracy of TBW non-reference field methods with a criterion method (i.e., deuterium dilution) in 118 adolescent athletes. Body volume was assessed by air displacement plethysmography, bone mineral was measured by dual-energy X-ray absorptiometry, and TBW by deuterium dilution. Non-reference TBW methods included 2 bioelectrical impedance analysis techniques (Tanita Body Composition Analyzer, model TBF-310) and bioelectrical impedance spectroscopy (BIS) (model 4000B); the Lohman's hydration constants of fat-free mass (FFM); and 3 derived anthropometric equations developed, respectively, by Kushner et al., Wells et al., and Morgenstern et al. The highest accuracy between TBW estimates and the reference model in both girls and boys was observed using the Lohman's constants (r2= 0.94, SEE = 1.56 kg; r2 = 0.92, SEE = 2.42 kg, respectively; p < 0.001), followed by both foot-to-foot Tanita (r2 = 0.88, SEE = 2.15 kg; r2 = 0.87, SEE = 3.01 kg, respectively; p < 0.001) and BIS (r2 = 0.92, SEE = 1.70 kg; r2 = 0.87, SEE = 3.04 kg, respectively; p < 0.001) with slopes and intercepts not significantly different from the line of identity. The regressions between anthropometric equations and the criterion method deviated from the line of identity (p < 0.05). The practical application of this study is that the specific constants of FFM hydration developed by Lohman seem to accurately estimate TBW in adolescent athletes. Foot-to-foot Tanita and BIS were also found to be valid and non-biased tools for predicting TBW. It would appear that the 3 anthropometric equations used are not appropriate for young athletes.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19568032     DOI: 10.1519/JSC.0b013e3181a9ec39

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  4 in total

1.  Effect of regional muscle damage and inflammation following eccentric exercise on electrical resistance and the body composition assessment using bioimpedance spectroscopy.

Authors:  Keisuke Shiose; Yoko Tanabe; Takahiro Ohnishi; Hideyuki Takahashi
Journal:  J Physiol Sci       Date:  2019-08-06       Impact factor: 2.781

2.  Validity of Bioimpedance Spectroscopy in the Assessment of Total Body Water and Body Composition in Wrestlers and Untrained Subjects.

Authors:  Keisuke Shiose; Emi Kondo; Rie Takae; Hiroyuki Sagayama; Keiko Motonaga; Yosuke Yamada; Yoshinari Uehara; Yasuki Higaki; Hideyuki Takahashi; Hiroaki Tanaka
Journal:  Int J Environ Res Public Health       Date:  2020-12-16       Impact factor: 3.390

3.  Cardiovascular Function in Different Phases of the Menstrual Cycle in Healthy Women of Reproductive Age.

Authors:  Malgorzata Kwissa; Tomasz Krauze; Agnieszka Mitkowska-Redman; Beata Banaszewska; Robert Z Spaczynski; Andrzej Wykretowicz; Przemyslaw Guzik
Journal:  J Clin Med       Date:  2022-10-03       Impact factor: 4.964

4.  Validity of hydration non-invasive indices during the weightcutting and official weigh-in for Olympic combat sports.

Authors:  Valentín E Fernández-Elías; Alberto Martínez-Abellán; José María López-Gullón; Ricardo Morán-Navarro; Jesús G Pallarés; Ernesto De la Cruz-Sánchez; Ricardo Mora-Rodriguez
Journal:  PLoS One       Date:  2014-04-16       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.