Literature DB >> 19565584

Soluble polymeric dual sensor for temperature and pH value.

Christian Pietsch1, Richard Hoogenboom, Ulrich S Schubert.   

Abstract

Year:  2009        PMID: 19565584     DOI: 10.1002/anie.200901071

Source DB:  PubMed          Journal:  Angew Chem Int Ed Engl        ISSN: 1433-7851            Impact factor:   15.336


× No keyword cloud information.
  9 in total

1.  A lysosome-targeting nanosensor for simultaneous fluorometric imaging of intracellular pH values and temperature.

Authors:  Wei Zhang; Y G Abou El-Reash; Longjiang Ding; Zhenzhen Lin; Ying Lian; Bo Song; Jingli Yuan; Xu-Dong Wang
Journal:  Mikrochim Acta       Date:  2018-11-06       Impact factor: 5.833

2.  Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications.

Authors:  Andreas Steinegger; Otto S Wolfbeis; Sergey M Borisov
Journal:  Chem Rev       Date:  2020-11-04       Impact factor: 60.622

Review 3.  Multi-stimuli responsive macromolecules and their assemblies.

Authors:  Jiaming Zhuang; Mallory R Gordon; Judy Ventura; Longyu Li; S Thayumanavan
Journal:  Chem Soc Rev       Date:  2013-06-13       Impact factor: 54.564

4.  A fluorescent thermometer based on a pyrene-labeled thermoresponsive polymer.

Authors:  Christian Pietsch; Antje Vollrath; Richard Hoogenboom; Ulrich S Schubert
Journal:  Sensors (Basel)       Date:  2010-08-27       Impact factor: 3.576

Review 5.  Responsive Boronic Acid-Decorated (Co)polymers: From Glucose Sensors to Autonomous Drug Delivery.

Authors:  Gertjan Vancoillie; Richard Hoogenboom
Journal:  Sensors (Basel)       Date:  2016-10-19       Impact factor: 3.576

6.  RAFT Emulsion Polymerization of Styrene Using a Poly((N,N-dimethyl acrylamide)-co-(N-isopropyl acrylamide)) mCTA: Synthesis and Thermosensitivity.

Authors:  Katharina Nieswandt; Prokopios Georgopanos; Martin Held; Evgeni Sperling; Volker Abetz
Journal:  Polymers (Basel)       Date:  2021-12-24       Impact factor: 4.329

7.  Flexible, Wearable and Fully-printed Smart Patch for pH and Hydration Sensing in Wounds.

Authors:  Mick Iversen; Monisha Monisha; Shweta Agarwala
Journal:  Int J Bioprint       Date:  2021-12-16

8.  Plasma dye coating as straightforward and widely applicable procedure for dye immobilization on polymeric materials.

Authors:  Lieselot De Smet; Gertjan Vancoillie; Peter Minshall; Kathleen Lava; Iline Steyaert; Ella Schoolaert; Elke Van De Walle; Peter Dubruel; Karen De Clerck; Richard Hoogenboom
Journal:  Nat Commun       Date:  2018-03-16       Impact factor: 14.919

9.  AIE-active non-conjugated poly(N-vinylcaprolactam) as a fluorescent thermometer for intracellular temperature imaging.

Authors:  Biswajit Saha; Bhuban Ruidas; Sourav Mete; Chitrangada Das Mukhopadhyay; Kamal Bauri; Priyadarsi De
Journal:  Chem Sci       Date:  2019-10-28       Impact factor: 9.825

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.