Cryoballoon pulmonary vein isolation guided by transesophageal echocardiography: novel aspects on an emerging ablation technique.

Claudia Herrera Siklódy1, Jan Minners, Martin Allgeier, Hans-Jürgen Allgeier, Nikolaus Jander, Reinhold Weber, Jochen Schiebeling-Römer, Franz-Josef Neumann, Dietrich Kalusche, Thomas Arentz.   

Abstract

BACKGROUND: Pulmonary vein (PV) isolation using a balloon-mounted cryoablation system is a new technology for the percutaneous treatment of atrial fibrillation (AF). Transesophageal echocardiography (TEE) allows real-time visualization of cryoballoon positioning and successful vein occlusion via color Doppler. We hypothesized that PV mechanical occlusion monitored with TEE could predict effective electrical isolation.
METHODS: We studied 124 PVs in 30 patients. Under continuous TEE assessment, a cryoballoon was placed in the antrum of each PV aiming for complete PV occlusion as documented by color Doppler. At the end of the procedure, PV electrical isolation was evaluated using a circumferential mapping catheter.
RESULTS: Of the 124 PVs studied, 123 (99.2%) could be visualized by TEE: the antrum was completely visualized in 80 of them (64.5%), partially in 36 (29.0%), and only disappearance of proximal flow could be observed in the remaining 7 PVs (5.7%). Vein occlusion could be achieved in 111 of the 123 (90.2%) visualized PVs. Postinterventional mapping demonstrated electrical isolation in 109 of 111 occluded PVs (positive predictive value 98.2%) and only in 1 of 12 nonoccluded PVs (negative predictive value 91.7%, P < 0.001). After a mean follow-up of 7.4 +/- 3.7 months, 73.3% of patients remained in sinus rhythm without antiarrhythmic drugs.
CONCLUSION: Color Doppler documented PV occlusion during cryoballoon ablation can predict effective electrical isolation.

Entities:  

Mesh:

Year:  2009        PMID: 19563358     DOI: 10.1111/j.1540-8167.2009.01524.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  13 in total

1.  Profuse and acute hemorrhagic gastroesophageal injury after cryotherapy in a cardiac surgery patient.

Authors:  Hyae-Jin Kim; Hyeon-Jeong Lee; Dowon Lee; Haekyu Kim; A-Rheum Cho; Soeun Jeon; Suyeon Hong
Journal:  J Thorac Dis       Date:  2017-07       Impact factor: 2.895

2.  Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation.

Authors:  Akihiro Sunaga; Masaharu Masuda; Mitsutoshi Asai; Osamu Iida; Shin Okamoto; Takayuki Ishihara; Kiyonori Nanto; Takashi Kanda; Takuya Tsujimura; Yasuhiro Matsuda; Syota Okuno; Toshiaki Mano
Journal:  J Interv Card Electrophysiol       Date:  2018-04-10       Impact factor: 1.900

Review 3.  The Use of Cryoballoon Ablation in Atrial Fibrillation: Simplifying Pulmonary Vein Isolation?

Authors:  Gian Battista Chierchia; Antonio Sorgente; Andrea Sarkozy; Carlo de Asmundis; Pedro Brugada
Journal:  J Atr Fibrillation       Date:  2010-12-15

4.  Direct pressure monitoring accurately predicts pulmonary vein occlusion during cryoballoon ablation.

Authors:  Ioanna Kosmidou; Shannnon Wooden; Brian Jones; Thomas Deering; Andrew Wickliffe; Dan Dan
Journal:  J Vis Exp       Date:  2013-02-26       Impact factor: 1.355

5.  Inner lumen mapping catheter-facilitated big cryoballoon treatment for atrial fibrillation shortens procedural duration and fluoroscopic exposure with comparable mid-term efficacy.

Authors:  Ngai-Yin Chan; Ho-Chuen Yuen; Pui-Shan Chu; Chi-Chung Choy; Hoi-Fan Chow; Ho-Fai Fong; Chun-Leung Lau; Ying-Keung Lo; Ping-Tim Tsui; Suet-Ting Lau; Ngai-Shing Mok
Journal:  J Interv Card Electrophysiol       Date:  2013-03-19       Impact factor: 1.900

Review 6.  Treating Atrial Fibrillation With Cryoballoon Technology.

Authors:  David R Altmann; Sven Knecht; Christian Sticherling; Peter Ammann; Beat Schaer; Stefan Osswald; Michael Kühne
Journal:  J Atr Fibrillation       Date:  2012-04-14

7.  Usefulness of Contrast Intracardiac Echocardiography in Performing Pulmonary Vein Balloon Occlusion during Cryo-ablation for Atrial Fibrillation.

Authors:  Domenico Catanzariti; Massimiliano Maines; Carlo Angheben; Maurizio Centonze; Claudio Cemin; Giuseppe Vergara
Journal:  Indian Pacing Electrophysiol J       Date:  2012-12-02

8.  Cryoballoon catheter ablation in atrial fibrillation.

Authors:  Cevher Ozcan; Jeremy Ruskin; Moussa Mansour
Journal:  Cardiol Res Pract       Date:  2011-06-20       Impact factor: 1.866

9.  Cryoballoon ablation for atrial fibrillation.

Authors:  Jason G Andrade; Marc Dubuc; Peter G Guerra; Laurent Macle; Lena Rivard; Denis Roy; Mario Talajic; Bernard Thibault; Paul Khairy
Journal:  Indian Pacing Electrophysiol J       Date:  2012-04-30

10.  Cryoballoon-to-Pulmonary Vein Occlusion Assessment via Capnography Technique: Where Does Occlusion Testing by End-Tidal CO2 Measurement "Fit" as a Predictor of Long-Term Efficacy?

Authors:  Robert A Pickett; Kimberly Owens; Penny Landis; Rahmani Sara; Hae W Lim
Journal:  J Atr Fibrillation       Date:  2018-06-30
View more