Literature DB >> 19562205

Dithizone nanofiber-coated membrane for filtration-enrichment and colorimetric detection of trace Hg(II) ion.

Yukiko Takahashi1, Supamas Danwittayakul, Toshishige M Suzuki.   

Abstract

Dithizone nanofiber-coated membranes (dithizone membranes), which are useful for sensitive and selective determination of Hg(II), were fabricated. Simply by filtration of the aqueous dispersion of dithizone nanofiber through a cellulose ester membrane filter, a dithizone nanofiber layer of less than 500 nm thickness was coated firmly and uniformly over the membrane filter surface. The steel blue color of the membrane remained unchanged for more than three months when fabricated in the presence of ascorbic acid and stored with an oxygen absorber in an evacuated aluminium bag. Determination at the parts per billion level of Hg(II) was achieved by filtration-enrichment of a sample solution and simultaneous colorimetric analysis using a TLC scanner (500 nm). Consequently, Hg(II) ion was concentrated in the dithizone layer as reddish brown complexes by filtration of a sample solution at pH 2.7. More than 90% of 10 ppb Hg(II) was retained in the dithizone layer at the filtration rate of 1.3-9.3 ml min(-1). The presence of Na+ (10,000 ppm), K+ (5000 ppm), Ca(II) (5000 ppm), Cu(II) (6.4 ppm), Fe(II) (100 ppm), Zn(II) (100 ppm), Pb(II) (100 ppm) and Cd(II) (10 ppm) by using 2.5 x 10(-4) M of ethylenediamine tetraacetic acid (EDTA) as a masking reagent did not interfere with the detection of Hg(II) (10 ppb). Most of anions did not interfere with the determination of Hg(II). The present method was tested for the detection of simulated wastewater, river water and seawater spiked with 10 ppb of Hg(II).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19562205     DOI: 10.1039/b816461d

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

1.  Photophysical Details and O2-Sensing Analysis of a Eu(III) Complex in Polymer Composite Nanofibers Prepared by Electrospinning.

Authors:  Chunguo Cui; Lina Song; Chao Li; Tiantian Lin; Kaiyao Shi
Journal:  Front Chem       Date:  2022-01-11       Impact factor: 5.221

2.  Facile Ag-Film Based Surface Enhanced Raman Spectroscopy Using DNA Molecular Switch for Ultra-Sensitive Mercury Ions Detection.

Authors:  Xiujie Liu; Mengmeng Liu; Yudong Lu; Changji Wu; Yunchao Xu; Duo Lin; Dechan Lu; Ting Zhou; Shangyuan Feng
Journal:  Nanomaterials (Basel)       Date:  2018-08-06       Impact factor: 5.076

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.