Literature DB >> 19560774

Effects of extra-column band spreading, liquid chromatography system operating pressure, and column temperature on the performance of sub-2-microm porous particles.

Kenneth J Fountain1, Uwe D Neue, Eric S Grumbach, Diane M Diehl.   

Abstract

The effects of extra-column band spreading, LC system operating pressure, and separation temperature were investigated for sub-2-microm particle columns using both a conventional HPLC system as well as a UPLC system. The contributions of both volume- and time-based extra-column effects were analyzed in detail. In addition, the performance difference between columns containing 2.5 and 1.7-microm particles (same stationary phase) was studied. The performance of these columns was compared using a conventional HPLC system and a low dead volume UPLC system capable of routine operation up to 1000 bar. The system contribution to band spreading and the pressure limitations of the conventional HPLC system were found to be the main difficulties that prevented acceptable performance of the sub-2-microm particle columns. Finally, an increase in operating temperature needs to be accompanied by an increase in flow rate to prevent a loss of separation performance. Thus, at a fixed column length, an increase in temperature is not a substitute for the need for very high operating pressures.

Mesh:

Substances:

Year:  2009        PMID: 19560774     DOI: 10.1016/j.chroma.2009.06.044

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Development of a 45kpsi ultrahigh pressure liquid chromatography instrument for gradient separations of peptides using long microcapillary columns and sub-2μm particles.

Authors:  Kaitlin M Grinias; Justin M Godinho; Edward G Franklin; Jordan T Stobaugh; James W Jorgenson
Journal:  J Chromatogr A       Date:  2016-09-26       Impact factor: 4.759

2.  Now, More Than Ever, Proteomics Needs Better Chromatography.

Authors:  Evgenia Shishkova; Alexander S Hebert; Joshua J Coon
Journal:  Cell Syst       Date:  2016-10-26       Impact factor: 10.304

3.  Effect of bioparticle size on dispersion and retention in monolithic and perfusive beds.

Authors:  Egor I Trilisky; Abraham M Lenhoff
Journal:  J Chromatogr A       Date:  2010-09-19       Impact factor: 4.759

4.  Size-Exclusion Chromatography for the Analysis of Protein Biotherapeutics and their Aggregates.

Authors:  Paula Hong; Stephan Koza; Edouard S P Bouvier
Journal:  J Liq Chromatogr Relat Technol       Date:  2012-11-30       Impact factor: 1.467

Review 5.  Are We Approaching a Speed Limit for the Chromatographic Separation of Enantiomers?

Authors:  Christopher J Welch
Journal:  ACS Cent Sci       Date:  2017-08-07       Impact factor: 14.553

6.  HPLC-CUPRAC post-column derivatization method for the determination of antioxidants: a performance comparison between porous silica and core-shell column packing.

Authors:  Syed A Haque; Socrates Jose P Cañete
Journal:  J Anal Sci Technol       Date:  2018-01-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.