Literature DB >> 19560703

Incidence of ventricular arrhythmias in patients on long-term support with a continuous-flow assist device (HeartMate II).

Mads Andersen1, Regitze Videbaek, Søren Boesgaard, Kåre Sander, Peter B Hansen, Finn Gustafsson.   

Abstract

The incidence of ventricular tachycardia (VT) or ventricular fibrillation (VF) in patients supported with a continuous-flow left ventricular assist device (LVAD) has not been investigated in detail. In 23 consecutive recipients of a HeartMate II, we analyzed the incidence of VT/VF during a total of 266 months of follow-up. Sustained VT or VF occurred in 52% of the patients, with the majority of arrhythmias occurring in the first 4 weeks after LVAD implantation. VT/VF requiring implantable cardioverter-defibrillator (ICD) shock or external defibrillation occurred in 8 patients and significant hemodynamic instability ensued in 3 patients. There were no clear predictors of VT/VF, and it is argued that prophylactic ICD implantation should be considered in patients supported with a continuous-flow LVAD.

Entities:  

Mesh:

Year:  2009        PMID: 19560703     DOI: 10.1016/j.healun.2009.03.011

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  26 in total

1.  Survival benefit of implantable cardioverter-defibrillators in left ventricular assist device-supported heart failure patients.

Authors:  Marwan M Refaat; Toshikazu Tanaka; Robert L Kormos; Dennis McNamara; Jeffrey Teuteberg; Steve Winowich; Barry London; Marc A Simon
Journal:  J Card Fail       Date:  2011-12-22       Impact factor: 5.712

Review 2.  Current Review of Implantable Cardioverter Defibrillator Use in Patients With Left Ventricular Assist Device.

Authors:  Jacinthe Boulet; Emmanuelle Massie; Blandine Mondésert; Yoan Lamarche; Michel Carrier; Anique Ducharme
Journal:  Curr Heart Fail Rep       Date:  2019-12

Review 3.  [Patients with implanted ventricular assist devices : Challenge for emergency medicine].

Authors:  M Bunz; C Kerscher; M Foltan; L Rupprecht; B M Graf; Y A Zausig
Journal:  Anaesthesist       Date:  2015-05       Impact factor: 1.041

Review 4.  Ventricular assist devices: pharmacological aspects of a mechanical therapy.

Authors:  O Wever-Pinzon; J Stehlik; A G Kfoury; J V Terrovitis; N A Diakos; C Charitos; D Y Li; S G Drakos
Journal:  Pharmacol Ther       Date:  2012-01-16       Impact factor: 12.310

5.  Clinical implications of left ventricular assist device implantation in patients with an implantable cardioverter-defibrillator.

Authors:  Fanny Boudghène-Stambouli; Stéphane Boulé; Céline Goéminne; Edward Botcherby; Christelle Marquié; Claude Kouakam; Laurence Guédon-Moreau; Guillaume Schurtz; Pascal de Groote; Nicolas Lamblin; Marie Fertin; Emmanuel Robin; François Brigadeau; Didier Klug; Dominique Lacroix; Jonathan Meurice; Ludivine Wissocque; André Vincentelli; Salem Kacet
Journal:  J Interv Card Electrophysiol       Date:  2013-12-13       Impact factor: 1.900

Review 6.  Ventricular Arrhythmias in Patients With Left Ventricular Assist Device (LVAD).

Authors:  Azza Ahmed; Mustapha Amin; Barry A Boilson; Ammar M Killu; Malini Madhavan
Journal:  Curr Treat Options Cardiovasc Med       Date:  2019-11-27

Review 7.  Treatment of ventricular tachycardia in patients with heart failure.

Authors:  Michael W Fong; Luanda Grazette; David Cesario; Michael Cao; Leslie Saxon
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

Review 8.  Mechanical circulatory support: devices, outcomes and complications.

Authors:  Carmelo A Milano; Alan A Simeone
Journal:  Heart Fail Rev       Date:  2013-01       Impact factor: 4.214

9.  Medical management of patients with continuous-flow left ventricular assist devices.

Authors:  Adam D Devore; Robert J Mentz; Chetan B Patel
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-02

Review 10.  Ventricular Tachycardia with ICD Shocks: When to Medicate and When to Ablate.

Authors:  Amir AbdelWahab; John Sapp
Journal:  Curr Cardiol Rep       Date:  2017-09-13       Impact factor: 2.931

View more