| Literature DB >> 19560266 |
M A El Mhammedi1, M Achak, M Hbid, M Bakasse, T Hbid, A Chtaini.
Abstract
In this work, determination of cadmium(II) using square wave voltammetry (SWV) was described. The method is based on accumulation of these metal ions on kaolin platinum electrode (K/Pt). The K/Pt performance was optimized with respect to the surface modification and operating conditions. The optimized conditions were obtained in pH of 5.0 and accumulation time of 25 min. Under the optimal conditions, the relationship between the peak current versus concentration was linear over the range of 9 x 10(-8) to 8.3 x 10(-6) mol L(-1). The detection limit (DL, 3sigma) was 5.4 x 10(-9) mol L(-1). The analytical methodology was successfully applied to monitor the Cd(II) content in natural water. Interferences were also evaluated.Entities:
Mesh:
Substances:
Year: 2009 PMID: 19560266 DOI: 10.1016/j.jhazmat.2009.05.024
Source DB: PubMed Journal: J Hazard Mater ISSN: 0304-3894 Impact factor: 10.588