Literature DB >> 19559832

A comparison of the Niti-D biliary uncovered stent and the uncovered Wallstent in malignant biliary obstruction.

Ki Young Yang1, Ji Kon Ryu, Jeong Kyun Seo, Sang Myung Woo, Joo Kyung Park, Yong-Tae Kim, Yong Bum Yoon.   

Abstract

BACKGROUND: The conformability of uncovered self-expandable metal stents (SEMSs) plays an important role in maintaining stent patency. However, whether increased conformability can prolong the duration of SEMS patency remains to be proved.
OBJECTIVE: The aim of this study was to examine the efficacy and complication rates of the Niti-D biliary uncovered metal stent (NDS), which is more conformable than the uncovered Wallstent.
DESIGN: Nonrandomized, retrospective study.
SETTING: Tertiary-care academic medical center. PATIENTS: From March 2005 to July 2007, 101 patients received an NDS (41 cases) or a Wallstent (60 cases) for malignant biliary obstruction.
INTERVENTIONS: SEMS placement.
RESULTS: Stent occlusion occurred in 11 patients (26.8%) with the NDS and 17 patients (28.3%) with the Wallstent. The median duration of stent patency tended to be longer for the NDS group (153 days) than for the Wallstent group (124 days); however, the difference was not statistically significant (P = .204). The median duration of overall survival of patients was 160 days for the NDS and 148 days for the Wallstent. The subgroup analysis showed that 27 patients had hilar obstruction (NDS 13, Wallstent 14). The median duration of stent patency was 249 days for the NDS group and 76 days for the Wallstent group; this difference was statistically significant (P = .006). The complications included pancreatitis in 3 NDS cases and 5 Wallstent cases. LIMITATION: The absence of prospective randomized recruitment.
CONCLUSION: The results of this study showed no significant differences between the NDS and the Wallstent for the palliative endoscopic management of malignant biliary obstruction. There were no significant differences in patency, complication rates, and patient survival between the more conformable NDS and the conventional Wallstent. However, the NDS, which has good conformability, may be preferred for hilar obstruction.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19559832     DOI: 10.1016/j.gie.2008.10.029

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  13 in total

1.  Endoscopic ultrasound-guided biliary drainage with placement of a fully covered metal stent for malignant biliary obstruction.

Authors:  Tae Hyeon Kim; Seong Hun Kim; Hyo Jeong Oh; Young Woo Sohn; Seung Ok Lee
Journal:  World J Gastroenterol       Date:  2012-05-28       Impact factor: 5.742

Review 2.  Drug eluting biliary stents to decrease stent failure rates: A review of the literature.

Authors:  Joseph Shatzel; Jisoo Kim; Kartik Sampath; Sharjeel Syed; Jennifer Saad; Zilla H Hussain; Kabir Mody; J Marc Pipas; Stuart Gordon; Timothy Gardner; Richard I Rothstein
Journal:  World J Gastrointest Endosc       Date:  2016-01-25

3.  A multicenter prospective study of the short-term outcome of a newly developed partially covered self-expandable metallic biliary stent (WallFlex(®)).

Authors:  Takayoshi Tsuchiya; Takao Itoi; Takuji Gotoda; Kensuke Kuraoka; Atsushi Sofuni; Fumihide Itokawa; Toshio Kurihara; Kentaro Ishii; Shujiro Tsuji; Nobuhito Ikeuchi; Reina Tanaka; Junko Umeda; Fuminori Moriyasu
Journal:  Dig Dis Sci       Date:  2011-02-06       Impact factor: 3.199

4.  Long-term risk of cholangitis in patients with metal stents for malignant biliary obstruction.

Authors:  Suresh Pola; Ramya Muralimohan; Benjamin Cohen; Syed M Abbas Fehmi; Thomas J Savides
Journal:  Dig Dis Sci       Date:  2012-04-28       Impact factor: 3.199

Review 5.  Endoscopic Palliation of Pancreatic Cancer.

Authors:  Vishal B Gohil; Jason B Klapman
Journal:  Curr Treat Options Gastroenterol       Date:  2017-09

6.  Newly designed large cell Niti-S stent for malignant hilar biliary obstruction: a pilot study.

Authors:  Hirofumi Kogure; Hiroyuki Isayama; Yousuke Nakai; Takeshi Tsujino; Yukiko Ito; Keisuke Yamamoto; Suguru Mizuno; Hiroshi Yagioka; Kazumichi Kawakubo; Takashi Sasaki; Kenji Hirano; Naoki Sasahira; Minoru Tada; Masao Omata; Kazuhiko Koike
Journal:  Surg Endosc       Date:  2010-07-03       Impact factor: 4.584

7.  Comparison of outcomes among secondary covered metallic, uncovered metallic, and plastic biliary stents in treating occluded primary metallic stents in malignant distal biliary obstruction.

Authors:  Jae Hee Cho; Tae Joo Jeon; Jeong Youp Park; Hee Man Kim; Yoon Jae Kim; Seung Woo Park; Jae Bock Chung; Si Young Song; Seungmin Bang
Journal:  Surg Endosc       Date:  2010-07-03       Impact factor: 4.584

8.  Evaluation of mechanical properties of self-expanding metal stents for optimization of tracheal collapse in dogs.

Authors:  Ji-Hyun Kim; Jin-Young Choi; Hun-Young Yoon
Journal:  Can J Vet Res       Date:  2022-07       Impact factor: 0.897

9.  Radiotherapy prolongs biliary metal stent patency in malignant pancreatobiliary obstructions.

Authors:  Semi Park; Jeong Youp Park; Seungmin Bang; Seung Woo Park; Jae Bock Chung; Si Young Song
Journal:  Gut Liver       Date:  2013-06-11       Impact factor: 4.519

10.  Surgical management of ERCP-related complications.

Authors:  Afshin Fathi; Farhad Lahmi; Rezvaneh Kozegaran
Journal:  Gastroenterol Hepatol Bed Bench       Date:  2011
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.