Literature DB >> 19559189

Remodeling of reconstructed left anterior descending coronary arteries with internal thoracic artery grafts.

Tomoki Shimokawa1, Susumu Manabe, Toshihiro Fukui, Shuichiro Takanashi.   

Abstract

BACKGROUND: The internal thoracic artery (ITA) remodels its diameter in response to flow requirements. The objective of this study was to elucidate the remodeling capacity of the reconstructed coronary artery using the ITA.
METHODS: We evaluated coronary angiograms in 63 patients who had left anterior descending artery (LAD) segmental reconstruction with or without endarterectomy after off-pump coronary artery bypass graft surgery. The diameters of the ITA and reconstructed coronary artery were measured early and at 1 year after surgery.
RESULTS: The mean diameter of the reconstructed LAD was significantly larger than that of the ITA, but significantly decreased 1 year after surgery (2.69 +/- 0.53 mm versus 1.87 +/- 0.39 mm; p > 0.0001). The proximal ratio, the ratio of the ITA to proximal reconstructed coronary artery, and the distal ratio, the ratio of the distal LAD to distal reconstructed coronary artery, increased to a value of almost 1.0 (0.77 +/- 0.11 versus 1.05 +/- 0.18, p < 0.0001, and 0.77 +/- 0.14 versus 0.92 +/- 0.12, p < 0.0001, respectively). Based on the mean diameter of the reconstructed coronary artery, there were no relationships between the use of endarterectomy and the degree of native coronary stenosis. The proximal ratio in the group with severe stenosis was significantly greater than that in the group with mild stenosis (1.08 +/- 0.18 versus 0.95 +/- 0.16; p = 0.036), although the distal ratio was not different between the two groups.
CONCLUSIONS: Vascular remodeling of the coronary artery reconstructed with the ITA is observed within 1 year after surgery.

Entities:  

Mesh:

Year:  2009        PMID: 19559189     DOI: 10.1016/j.athoracsur.2009.03.019

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

1.  Surgical treatment of entrapped intravascular ultrasonography catheter.

Authors:  Yusuke Shimahara; Junjiro Kobayashi; Hiroyuki Nakajima; Koichi Toda; Tomoyuki Fujita
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-02-12

2.  Segmental clamp and distal perfusion technique for reducing myocardial ischemia during coronary onlay grafting on a beating heart.

Authors:  Naoki Minato; Takayuki Okada; Shinya Kanemoto; Nobuya Zempo
Journal:  Surg Today       Date:  2018-01-09       Impact factor: 2.549

Review 3.  Coronary endarterectomy for the diffusely diseased coronary artery.

Authors:  Kosaku Nishigawa; Toshihiro Fukui; Shuichiro Takanashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-05-10

4.  Surgical myocardial revascularization of patients with ischemic cardiomyopathy and severe left ventricular disfunction.

Authors:  André L Hovnanian; Alexandre de Matos Soeiro; Carlos Vicente Serrano; Sérgio Almeida de Oliveira; Fábio B Jatene; Noedir A G Stolf; José A F Ramires
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

5.  Coronary endarterectomy for diffusely diseased coronary artery: An ace in the hole in coronary artery surgery.

Authors:  Kosaku Nishigawa; Toshihiro Fukui; Jun Takaki; Shuichiro Takanashi
Journal:  JTCVS Tech       Date:  2021-03-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.