PURPOSE: To assess the transferability of the magnetic resonance imaging (MRI) multislice multiecho T2(*) technique for global and segmental measurement of iron overload in thalassemia patients. MATERIALS AND METHODS: Multiecho T2(*) sequences were installed on six MRI scanners. Five healthy subjects (n = 30) were scanned at each site; five thalassemia major (TM) patients were scanned at the reference site and were rescanned locally (n = 25) within 1 month. T2(*) images were analyzed using previously validated software. RESULTS: T2(*) values of healthy subjects showed intersite homogeneity. On TM patients, for global heart T2(*) values the correlation coefficient was 0.97, coefficients of variation (CoV(s)) ranged from 0.04-0.12, and intraclass coefficients (ICC(s)) ranged from 0.94-0.99. The mean CoV and ICC for segmental T2(*) distribution were 0.198 and 88, respectively. CONCLUSION: The multislice multiecho T2(*) technique is transferable among scanners with good reproducibility. (c) 2009 Wiley-Liss, Inc.
PURPOSE: To assess the transferability of the magnetic resonance imaging (MRI) multislice multiecho T2(*) technique for global and segmental measurement of iron overload in thalassemiapatients. MATERIALS AND METHODS: Multiecho T2(*) sequences were installed on six MRI scanners. Five healthy subjects (n = 30) were scanned at each site; five thalassemia major (TM) patients were scanned at the reference site and were rescanned locally (n = 25) within 1 month. T2(*) images were analyzed using previously validated software. RESULTS: T2(*) values of healthy subjects showed intersite homogeneity. On TM patients, for global heart T2(*) values the correlation coefficient was 0.97, coefficients of variation (CoV(s)) ranged from 0.04-0.12, and intraclass coefficients (ICC(s)) ranged from 0.94-0.99. The mean CoV and ICC for segmental T2(*) distribution were 0.198 and 88, respectively. CONCLUSION: The multislice multiecho T2(*) technique is transferable among scanners with good reproducibility. (c) 2009 Wiley-Liss, Inc.
Authors: Rafael Heiss; Marco Wiesmueller; Christoph Treutlein; Hannes Seuss; Michael Uder; Matthias May; Wolfgang Wuest Journal: Int J Cardiovasc Imaging Date: 2018-11-21 Impact factor: 2.357
Authors: E Di Cesare; F Cademartiri; I Carbone; A Carriero; M Centonze; F De Cobelli; R De Rosa; P Di Renzi; A Esposito; R Faletti; R Fattori; M Francone; A Giovagnoni; L La Grutta; G Ligabue; L Lovato; R Marano; M Midiri; A Romagnoli; V Russo; F Sardanelli; L Natale; J Bogaert; A De Roos Journal: Radiol Med Date: 2012-11-26 Impact factor: 3.469