In vivo response to cross-linked polyethylene and polycarbonate-urethane particles.

Richard A Smith1, Anobel Maghsoodpour, Nadim James Hallab.   

Abstract

This study was undertaken to examine macrophage response to polycarbonate-urethane, a proposed alternative material to polyethylene in acetabular components of total hip arthroplasty. Polyethylene wear debris from total joint replacements has been linked to osteolysis and implant lifespan. It has been shown in vitro, that polyethylene particles cleaned of endotoxin generate less of an inflammatory cytokine response than endotoxin bound particles. Comparative particle induced effects on implant fixation were tested using endotoxin free cross-linked ultra-high molecular weight polyethylene (x-UHMWPE) and polycarbonate-urethane (PCU) particles with and without intraperitoneal injection (IP) of lipopolysaccharide (LPS) using a Ti-alloy femoral intramedullary nail rat model. MicroCT and mechanical testing assessment of peri-implant bone indicated significantly less bone and lower fixation strength, respectively, when the implant was surrounded by xUHMWPE particles compared to PCU particles (with and without LPS IP). This indicates particles of PCU may be less disruptive to bone-implant fixation than x-UHMWPE in vivo, under both LPS free and challenged conditions.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19557792     DOI: 10.1002/jbm.a.32531

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  9 in total

1.  Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening.

Authors:  Shuo Liu; Amarjit S Virdi; Kotaro Sena; W Frank Hughes; Dale R Sumner
Journal:  J Biomed Mater Res A       Date:  2012-01-24       Impact factor: 4.396

Review 2.  Mediators of the inflammatory response to joint replacement devices.

Authors:  Neil Cobelli; Brian Scharf; Giovanna M Crisi; John Hardin; Laura Santambrogio
Journal:  Nat Rev Rheumatol       Date:  2011-09-06       Impact factor: 20.543

3.  Sophocarpine attenuates wear particle-induced implant loosening by inhibiting osteoclastogenesis and bone resorption via suppression of the NF-κB signalling pathway in a rat model.

Authors:  Chen-He Zhou; Zhong-Li Shi; Jia-Hong Meng; Bin Hu; Chen-Chen Zhao; Yu-Te Yang; Wei Yu; Ze-Xin Chen; Boon Chin Heng; Virginia-Jeni Akila Parkman; Shuai Jiang; Han-Xiao Zhu; Hao-Bo Wu; Wei-Liang Shen; Shi-Gui Yan
Journal:  Br J Pharmacol       Date:  2018-02-14       Impact factor: 8.739

4.  The gut microbiota may be a novel pathogenic mechanism in loosening of orthopedic implants in rats.

Authors:  Meghan M Moran; Brittany M Wilson; Jun Li; Phillip A Engen; Ankur Naqib; Stefan J Green; Amarjit S Virdi; Anna Plaas; Christopher B Forsyth; Ali Keshavarzian; Dale R Sumner
Journal:  FASEB J       Date:  2020-09-15       Impact factor: 5.191

5.  Arthrotomy-based preclinical models of particle-induced osteolysis: A systematic review.

Authors:  Meghan M Moran; Brittany M Wilson; Ryan D Ross; Amarjit S Virdi; Dale Rick Sumner
Journal:  J Orthop Res       Date:  2017-06-28       Impact factor: 3.494

6.  Chondroprotective effects of a polycarbonate-urethane meniscal implant: histopathological results in a sheep model.

Authors:  Gal Zur; Eran Linder-Ganz; Jonathan J Elsner; Jonathan Shani; Ori Brenner; Gabriel Agar; Elliott B Hershman; Steven P Arnoczky; Farshid Guilak; Avi Shterling
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-16       Impact factor: 4.342

7.  Early changes in serum osteocalcin and body weight are predictive of implant fixation in a rat model of implant loosening.

Authors:  Brittany M Wilson; Meghan M Moran; Matthew J Meagher; Ryan D Ross; Maleeha Mashiatulla; Amarjit S Virdi; Dale R Sumner
Journal:  J Orthop Res       Date:  2019-12-25       Impact factor: 3.494

8.  A comparative multi-parametric in vitro model identifies the power of test conditions to predict the fibrotic tendency of a biomaterial.

Authors:  Maren Jannasch; Sabine Gaetzner; Tobias Weigel; Heike Walles; Tobias Schmitz; Jan Hansmann
Journal:  Sci Rep       Date:  2017-05-10       Impact factor: 4.379

9.  Study of the polycarbonate-urethane/metal contact in different positions during gait cycle.

Authors:  Sergio Gabarre; Antonio Herrera; Jesús Mateo; Elena Ibarz; Antonio Lobo-Escolar; Luis Gracia
Journal:  Biomed Res Int       Date:  2014-08-27       Impact factor: 3.411