Literature DB >> 19557024

Miyake-Apple study of the rotational stability of the Acrysof Toric intraocular lens after experimental eye trauma.

F A S Pereira1, E J Milverton, M T Coroneo.   

Abstract

PURPOSE: To evaluate the rotational stability of the Acrysof Toric intraocular lens (IOL) after experimental eye trauma.
METHODS: Two human cadaver eyes were prepared in accordance with the Miyake-Apple technique, with closed-system modification. After phacoemulsification, an Acrysof Toric IOL was implanted in the capsular bag. Experimental traumatisation of the globe was achieved by pressing against the eye wall using a cotton tip or a fingertip, whereas the IOL was observed from the posterior view. Digital photographs of the eye before and after the procedures were overlaid to detect and measure rotation of the IOL.
RESULTS: The IOL rotated 5.80 degrees when the traumatic procedures did not cause important leakage from the incision. When the traumatic procedures caused important leakage from the incision and anterior chamber collapse, the IOL rotated 41.00 degrees.
CONCLUSION: Ocular trauma can cause rotation of the Acrysof Toric IOL. In the event of an eye trauma with no or insignificant leakage from the incision, the IOL rotates less than when the trauma causes significant leakage from the incision.

Entities:  

Mesh:

Year:  2009        PMID: 19557024     DOI: 10.1038/eye.2009.150

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  7 in total

1.  Response to comments on: Visual outcome and refractive status with monofocal toric intraocular lens implantation to correct astigmatism during cataract surgery.

Authors:  Mayuri S Patil; Archana S Nikose
Journal:  Indian J Ophthalmol       Date:  2021-05       Impact factor: 1.848

Review 2.  Cataract surgery and methods of wound closure: a review.

Authors:  Cynthia Matossian; Sarah Makari; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-05-22

3.  Toric Intraocular Lens for Astigmatism Correction in Cataract Patients.

Authors:  Hassan Razmjoo; Mohammad Ghoreishi; Azadeh Mohammadi Milasi; Alireza Peyman; Zahra Jafarzadeh; Mohadeseh Mohammadinia; Nasrollahi Kobra
Journal:  Adv Biomed Res       Date:  2017-10-16

4.  Visual outcome and refractive status with monofocal toric intraocular lens implantation to correct astigmatism during cataract surgery.

Authors:  Mayuri Sh Patil; Archana S Nikose; Shadwala Bharti
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

5.  Toric intraocular lens implantation - atypical cases.

Authors:  Alina Simona Lazăr; Bogdana Tăbăcaru; Simona Stanca; Tudor Horia Stanca
Journal:  Rom J Ophthalmol       Date:  2020 Oct-Dec

6.  Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens.

Authors:  Wojciech Lubiński; Beata Kaźmierczak; Jolanta Gronkowska-Serafin; Karolina Podborączyńska-Jodko
Journal:  J Ophthalmol       Date:  2016-02-28       Impact factor: 1.909

7.  Comparison of the clinical efficacy of AcrySof® IQ and TECNIS® toric intraocular lenses: A real-world study.

Authors:  Juan-Juan Yang; Ya-Zhou Qin; Li Qin; Jing-Ming Li
Journal:  Exp Ther Med       Date:  2020-08-28       Impact factor: 2.447

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.