Bacteriological water quality in the central dialysis fluid delivery system from the survey of the Japanese Society for Dialysis Therapy.

Ikuto Masakane1, Yoshiaki Takemoto, Shigeru Nakai, Yoshiharu Tsubakihara, Takashi Akiba, Yuzo Watanabe, Kunitoshi Iseki.   

Abstract

The Japanese Society for Dialysis Therapy (JSDT) surveyed all dialysis facilities for bacteriological quality of dialysis fluid and quality controls for dialysis fluid in 2006 and 2007. The JSDT collected the data for endotoxin (ET) levels, bacterial count and usage of ET retentive filters (ETRF). The JSDT standard for ET level in dialysis fluid (<0.050 EU/ml) was achieved in 89.0% in 2006 and in 93.6% in 2007. The JSDT standard for bacterial cell counts in dialysis fluid (<100 cfu/ml) was achieved in 96.9% in 2006 and in 97.4% in 2007. The central dialysis fluid delivery system (CDDS) is a unique system developed in Japan which has easy handling for daily maintenance of delivery systems, but it has been pointed out that CDDS has a weak point for the protection of biofilms. However, the bacteriological water qualities of dialysis fluid in CDDS were proven to be extremely high in most Japanese dialysis facilities by JSDT surveys. Bacteriological water quality has a strong impact on the patient outcome. The acceptable level of ET of dialysis fluid should be <0.1 EU/ml based on the results of JSDT survey. The excellent water quality in CDDS might be one of the important factors which help good patient survival in chronic dialysis in Japan. (c) 2009 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19556757     DOI: 10.1159/000213491

Source DB:  PubMed          Journal:  Blood Purif        ISSN: 0253-5068            Impact factor:   2.614


  6 in total

1.  Bacteriological Quality of Treated Water and Dialysate in Haemodialysis Unit of A Tertiary Care Hospital.

Authors:  Shiva Verma; V A Indumathi; K C Gurudev; Shalini Ashok Naik
Journal:  J Clin Diagn Res       Date:  2015-10-01

2.  Japanese society for dialysis therapy renal data registry-a window through which we can view the details of Japanese dialysis population.

Authors:  Norio Hanafusa; Shigeru Nakai; Kunitoshi Iseki; Yoshiharu Tsubakihara
Journal:  Kidney Int Suppl (2011)       Date:  2015-06

3.  Efficacy of Biofilm Removal From Hemodialysis Piping.

Authors:  Yutaka Isakozawa; Heihachi Migita; Shingo Takesawa
Journal:  Nephrourol Mon       Date:  2016-08-13

4.  Effect of dialyzer membrane materials on survival in chronic hemodialysis patients: Results from the annual survey of the Japanese Nationwide Dialysis Registry.

Authors:  Masanori Abe; Takayuki Hamano; Atsushi Wada; Shigeru Nakai; Ikuto Masakane
Journal:  PLoS One       Date:  2017-09-14       Impact factor: 3.240

5.  Super high-flux membrane dialyzers improve mortality in patients on hemodialysis: a 3-year nationwide cohort study.

Authors:  Masanori Abe; Ikuto Masakane; Atsushi Wada; Shigeru Nakai; Kosaku Nitta; Hidetomo Nakamoto
Journal:  Clin Kidney J       Date:  2021-09-28

6.  Green nephrology and eco-dialysis: a position statement by the Italian Society of Nephrology.

Authors:  Giorgina Barbara Piccoli; Adamasco Cupisti; Filippo Aucella; Giuseppe Regolisti; Carlo Lomonte; Martina Ferraresi; D'Alessandro Claudia; Carlo Ferraresi; Roberto Russo; Vincenzo La Milia; Bianca Covella; Luigi Rossi; Antoine Chatrenet; Gianfranca Cabiddu; Giuliano Brunori
Journal:  J Nephrol       Date:  2020-04-15       Impact factor: 3.902

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.