Use of saliva-based nano-biochip tests for acute myocardial infarction at the point of care: a feasibility study.

Pierre N Floriano1, Nicolaos Christodoulides, Craig S Miller, Jeffrey L Ebersole, John Spertus, Beate G Rose, Denis F Kinane, M John Novak, Steven Steinhubl, Shelley Acosta, Sanghamitra Mohanty, Priya Dharshan, Chih-ko Yeh, Spencer Redding, Wieslaw Furmaga, John T McDevitt.   

Abstract

BACKGROUND: For adults with chest pain, the electrocardiogram (ECG) and measures of serum biomarkers are used to screen and diagnose myocardial necrosis. These measurements require time that can delay therapy and affect prognosis. Our objective was to investigate the feasibility and utility of saliva as an alternative diagnostic fluid for identifying biomarkers of acute myocardial infarction (AMI).
METHODS: We used Luminex and lab-on-a-chip methods to assay 21 proteins in serum and unstimulated whole saliva procured from 41 AMI patients within 48 h of chest pain onset and from 43 apparently healthy controls. Data were analyzed by use of logistic regression and area under curve (AUC) for ROC analysis to evaluate the diagnostic utility of each biomarker, or combinations of biomarkers, in screening for AMI.
RESULTS: Both established and novel cardiac biomarkers demonstrated significant differences in concentrations between patients with AMI and controls without AMI. The saliva-based biomarker panel of C-reactive protein, myoglobin, and myeloperoxidase exhibited significant diagnostic capability (AUC = 0.85, P < 0.0001) and in conjunction with ECG yielded strong screening capacity for AMI (AUC = 0.96) comparable to that of the panel (brain natriuretic peptide, troponin-I, creatine kinase-MB, myoglobin; AUC = 0.98) and far exceeded the screening capacity of ECG alone (AUC approximately 0.6). En route to translating these findings to clinical practice, we adapted these unstimulated whole saliva tests to a novel lab-on-a-chip platform for proof-of-principle screens for AMI.
CONCLUSIONS: Complementary to ECG, saliva-based tests within lab-on-a-chip systems may provide a convenient and rapid screening method for cardiac events in prehospital stages for AMI patients.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19556448     DOI: 10.1373/clinchem.2008.117713

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  58 in total

1.  Perspective on diagnostics for global health.

Authors:  Elain Fu; Paul Yager; Pierre N Floriano; Nicolaos Christodoulides; John T McDevitt
Journal:  IEEE Pulse       Date:  2011-11       Impact factor: 0.924

Review 2.  Current development of saliva/oral fluid-based diagnostics.

Authors:  Chih-Ko Yeh; Nicolaos J Christodoulides; Pierre N Floriano; Craig S Miller; Jeffrey L Ebersole; Shannon E Weigum; John McDevitt; Spencer W Redding
Journal:  Tex Dent J       Date:  2010-07

Review 3.  Emerging applications of nanotechnology for the diagnosis and management of vulnerable atherosclerotic plaques.

Authors:  Shann S Yu; Ryan A Ortega; Brendan W Reagan; John A McPherson; Hak-Joon Sung; Todd D Giorgio
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-08-10

Review 4.  Emerging applications of nanomedicine for the diagnosis and treatment of cardiovascular diseases.

Authors:  Biana Godin; Jason H Sakamoto; Rita E Serda; Alessandro Grattoni; Ali Bouamrani; Mauro Ferrari
Journal:  Trends Pharmacol Sci       Date:  2010-02-19       Impact factor: 14.819

Review 5.  Saliva as a diagnostic fluid.

Authors:  Daniel Malamud
Journal:  Dent Clin North Am       Date:  2011-01

6.  Application of programmable bio-nano-chip system for the quantitative detection of drugs of abuse in oral fluids.

Authors:  Nicolaos Christodoulides; Richard De La Garza; Glennon W Simmons; Michael P McRae; Jorge Wong; Thomas F Newton; Regina Smith; James J Mahoney; Justin Hohenstein; Sobeyda Gomez; Pierre N Floriano; Humberto Talavera; Daniel J Sloan; David E Moody; David M Andrenyak; Thomas R Kosten; Ahmed Haque; John T McDevitt
Journal:  Drug Alcohol Depend       Date:  2015-05-22       Impact factor: 4.492

7.  Translational and clinical applications of salivary diagnostics.

Authors:  W V Giannobile; J T McDevitt; R S Niedbala; D Malamud
Journal:  Adv Dent Res       Date:  2011-10

8.  Whole-saliva proteolysis and its impact on salivary diagnostics.

Authors:  K Thomadaki; E J Helmerhorst; N Tian; X Sun; W L Siqueira; D R Walt; F G Oppenheim
Journal:  J Dent Res       Date:  2011-09-13       Impact factor: 6.116

9.  Next Generation Programmable Bio-Nano-Chip System for On-Site Detection in Oral Fluids.

Authors:  Nicolaos Christodoulides; Richard De La Garza; Glennon W Simmons; Michael P McRae; Jorge Wong; Thomas F Newton; Thomas R Kosten; Ahmed Haque; John T McDevitt
Journal:  J Drug Abuse       Date:  2015-11-23

Review 10.  Current developments in salivary diagnostics.

Authors:  Craig S Miller; Joseph D Foley; Alison L Bailey; Charles L Campell; Roger L Humphries; Nicolaos Christodoulides; Pierre N Floriano; Glennon Simmons; Bryon Bhagwandin; James W Jacobson; Spencer W Redding; Jeffrey L Ebersole; John T McDevitt
Journal:  Biomark Med       Date:  2010-02       Impact factor: 2.851