Literature DB >> 19553100

Comparison of surface plasmon resonance and capacitive immunosensors for cancer antigen 125 detection in human serum samples.

Siriwan Suwansa-ard1, Proespichaya Kanatharana, Punnee Asawatreratanakul, Booncharoen Wongkittisuksa, Chusak Limsakul, Panote Thavarungkul.   

Abstract

This paper presents a comparison between surface plasmon resonance (SPR) and capacitive immunosensors for a flow injection label-free detection of cancer antigen 125 (CA 125) in human serum. Anti-CA 125 was immobilized on gold surface through a self-assembled monolayer. Parameters affecting the responses of each system were optimized. Under optimal conditions, SPR provided a detection limit of 0.1 U ml(-1) while 0.05 U ml(-1) was obtained for the capacitive system. Linearity for SPR was between 0.1 and 40 U ml(-1) and 0.05-40 U ml(-1) for capacitive system. These immunosensors were applied to analyze CA 125 concentrations in human serum samples and compared with conventional enzyme linked fluorescent assay (ELFA). Both systems showed good agreement with ELFA (P<0.05). Moreover, these immunosensors were very stable and provided good reproducible responses after regeneration, up to 32 times for SPR and 48 times for capacitive system with relative standard deviation lower than 4%. The SPR immunosensor provided advantages in term of fast response and real-time monitoring while capacitive immunosensor offered a sensitive and cost-effective method for CA 125 detection.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19553100     DOI: 10.1016/j.bios.2009.04.008

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Recent advancements in fabrication of nanomaterial based biosensors for diagnosis of ovarian cancer: a comprehensive review.

Authors:  Rinky Sha; Sushmee Badhulika
Journal:  Mikrochim Acta       Date:  2020-02-19       Impact factor: 5.833

2.  Immunoassays for the cancer biomarker CA125 based on a large-birefringence nematic liquid-crystal mixture.

Authors:  Shih-Hung Sun; Mon-Juan Lee; Yun-Han Lee; Wei Lee; Xiaolong Song; Chao-Yuan Chen
Journal:  Biomed Opt Express       Date:  2014-12-23       Impact factor: 3.732

3.  Stimulus-responsive hydrogels: Theory, modern advances, and applications.

Authors:  Michael C Koetting; Jonathan T Peters; Stephanie D Steichen; Nicholas A Peppas
Journal:  Mater Sci Eng R Rep       Date:  2015-05-16       Impact factor: 36.214

4.  Proteomic technologies for the study of osteosarcoma.

Authors:  Stephanie D Byrum; Charity L Washam; Corey O Montgomery; Alan J Tackett; Larry J Suva
Journal:  Sarcoma       Date:  2012-03-06

5.  Surface plasmon resonance immunosensor for label-free detection of BIRC5 biomarker in spontaneously occurring canine mammary tumours.

Authors:  Subas Chandra Jena; Sameer Shrivastava; Sonal Saxena; Naveen Kumar; Swapan Kumar Maiti; Bishnu Prasad Mishra; Raj Kumar Singh
Journal:  Sci Rep       Date:  2019-09-17       Impact factor: 4.379

Review 6.  Early lung cancer diagnosis by biosensors.

Authors:  Yuqian Zhang; Dongliang Yang; Lixing Weng; Lianhui Wang
Journal:  Int J Mol Sci       Date:  2013-07-25       Impact factor: 5.923

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.