Literature DB >> 19550859

Speckle noise reduction algorithm for optical coherence tomography based on interval type II fuzzy set.

Prabakar Puvanathasan, Kostadinka Bizheva.   

Abstract

A novel speckle reduction technique based on soft thresholding of wavelet coefficients using interval type II fuzzy system was developed for reducing speckle noise in Optical Coherence Tomography images. The proposed algorithm is an extension of a recently published method for filtering additive Gaussian noise by use of type I fuzzy system. Unlike type I, interval type II fuzzy based thresholding filter considers the uncertainty in the calculated threshold and the wavelet coefficient is adjusted based on this uncertainty. A single parameter controls the signal-to-noise (SNR) improvement. Application of this novel algorithm to optical coherence tomograms acquired in-vivo from a human finger tip show reduction in the speckle noise with little edge blurring and image SNR improvement of about 10dB. Comparison with adaptive Wiener and adaptive Lee filters, applied to the same image, demonstrated the superior performance of the fuzzy type II algorithm in terms of image metrics improvement.

Entities:  

Year:  2007        PMID: 19550859     DOI: 10.1364/oe.15.015747

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  18 in total

Review 1.  Retinal imaging and image analysis.

Authors:  Michael D Abràmoff; Mona K Garvin; Milan Sonka
Journal:  IEEE Rev Biomed Eng       Date:  2010

2.  Speckle attenuation in optical coherence tomography by curvelet shrinkage.

Authors:  Zhongping Jian; Zhaoxia Yu; Lingfeng Yu; Bin Rao; Zhongping Chen; Bruce J Tromberg
Journal:  Opt Lett       Date:  2009-05-15       Impact factor: 3.776

3.  Stochastic speckle noise compensation in optical coherence tomography using non-stationary spline-based speckle noise modelling.

Authors:  Andrew Cameron; Dorothy Lui; Ameneh Boroomand; Jeffrey Glaister; Alexander Wong; Kostadinka Bizheva
Journal:  Biomed Opt Express       Date:  2013-08-28       Impact factor: 3.732

4.  Aperture phase modulation with adaptive optics: a novel approach for speckle reduction and structure extraction in optical coherence tomography.

Authors:  Pengfei Zhang; Suman K Manna; Eric B Miller; Yifan Jian; Ratheesh K Meleppat; Marinko V Sarunic; Edward N Pugh; Robert J Zawadzki
Journal:  Biomed Opt Express       Date:  2019-01-15       Impact factor: 3.732

5.  High dynamic range imaging concept-based signal enhancement method reduced the optical coherence tomography measurement variability.

Authors:  Hiroshi Ishikawa; Chieh-Li Chen; Gadi Wollstein; Jonathan L Grimm; Yun Ling; Richard A Bilonick; Ian A Sigal; Larry Kagemann; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-01-30       Impact factor: 4.799

6.  Speckle reduction in optical coherence tomography images based on wave atoms.

Authors:  Yongzhao Du; Gangjun Liu; Guoying Feng; Zhongping Chen
Journal:  J Biomed Opt       Date:  2014-05       Impact factor: 3.170

7.  Modified nonlinear complex diffusion filter (MNCDF).

Authors:  Kalpana Saini; M L Dewal; Manojkumar Rohit
Journal:  J Echocardiogr       Date:  2012-03-28

8.  Adaptive anisotropic diffusion for noise reduction of phase images in Fourier domain Doppler optical coherence tomography.

Authors:  Shaoyan Xia; Yong Huang; Shizhao Peng; Yanfeng Wu; Xiaodi Tan
Journal:  Biomed Opt Express       Date:  2016-07-05       Impact factor: 3.732

9.  Denoising and 4D visualization of OCT images.

Authors:  Madhusudhana Gargesha; Michael W Jenkins; Andrew M Rollins; David L Wilson
Journal:  Opt Express       Date:  2008-08-04       Impact factor: 3.894

10.  Three-dimensional speckle suppression in Optical Coherence Tomography based on the curvelet transform.

Authors:  Zhongping Jian; Lingfeng Yu; Bin Rao; Bruce J Tromberg; Zhongping Chen
Journal:  Opt Express       Date:  2010-01-18       Impact factor: 3.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.