| Literature DB >> 19550507 |
Ian C M Littler1, Malcolm B Gray, Jong H Chow, Daniel A Shaddock, David E McClelland.
Abstract
An integrated sensor system is presented which displays passive long range operation to 100 km at pico-strain (pepsilon) sensitivity to low frequencies (4 Hz) in wavelength division multiplexed operation with negligible cross-talk (better than -75 dB). This has been achieved by pre-stabilizing and multiplexing all interrogation lasers for the sensor array to a single optical frequency reference. This single frequency reference allows each laser to be locked to an arbitrary wavelength and independently tuned, while maintaining suppression of laser frequency noise. With appropriate packaging, such a multiplexed strain sensing system can form the core of a low frequency accelerometer or hydrophone array.Year: 2009 PMID: 19550507 DOI: 10.1364/oe.17.011077
Source DB: PubMed Journal: Opt Express ISSN: 1094-4087 Impact factor: 3.894