3D echocardiography: evaluation of the right ventricle.

Takahiro Shiota1.   

Abstract

PURPOSE OF REVIEW: Evaluation of right ventricular (RV) volume, function and mass has been challenging because of its unique cavity geometry. However, it is indispensable, especially in patients with signs of right-sided heart failure and those with congenital heart diseases. Thus, many investigations on the RV have been published to this end. Although clinical investigations of the RV have been focused on the use of 2-dimenisonal (2D) echocardiography, progressive development of three-dimensional (3D) echocardiography has made it possible to evaluate the RV in clinical settings lately. RECENT
FINDINGS: Accuracy of newly developed real-time 3D echocardiography for determining RV volume and function has been reported with the use of magnetic resonance imaging (MRI). A slight but significant underestimation of MRI derived RV volumes by 3D echocardiographic methods have been found in multiple recent human studies. One of the in-vitro studies rightly reported the importance of technical factors, causing the inaccuracy of 3D echocardiography.
SUMMARY: Despite the development of new real-time 3D echocardiographic systems, there still exist limitations in clinical settings due to technical factors. Thus, the combination of conventional 2D and Doppler methods and 3D echocardiography is recommended in the evaluation of the RV at the present time.

Entities:  

Mesh:

Year:  2009        PMID: 19550311     DOI: 10.1097/HCO.0b013e32832cf8f6

Source DB:  PubMed          Journal:  Curr Opin Cardiol        ISSN: 0268-4705            Impact factor:   2.161


  6 in total

1.  Evaluation of right ventricular function using single-beat three-dimensional echocardiography in neonate.

Authors:  Kazuhiro Watanabe; Ikuo Hashimoto; Keijiro Ibuki; Mako Okabe; Hisashi Kaneda; Fukiko Ichida
Journal:  Pediatr Cardiol       Date:  2015-01-15       Impact factor: 1.655

2.  Right ventricular geometry and mechanics in patients with obstructive sleep apnea living at high altitude.

Authors:  Tolga Sinan Güvenç; Nergiz Hüseyinoğlu; Serkan Özben; Şeref Kul; Rengin Çetin; Kaya Özen; Coşkun Doğan; Bahattin Balci
Journal:  Sleep Breath       Date:  2015-04-19       Impact factor: 2.816

3.  A Hybrid Method for Endocardial Contour Extraction of Right Ventricle in 4-Slices from 3D Echocardiography Dataset.

Authors:  Faten A Dawood; Rahmita W Rahmat; Suhaini B Kadiman; Lili N Abdullah; Mohd D Zamrin
Journal:  Adv Bioinformatics       Date:  2014-10-12

4.  Quantification of Initial Right Ventricular Dimensions by Computed Tomography in Infants with Congenital Heart Disease and a Hypoplastic Right Ventricle.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2020-02       Impact factor: 3.500

5.  Comparison between Automatic and Semiautomatic System for the 3D Echocardiographic Multiparametric Evaluation of RV Function and Dimension.

Authors:  Marco Penso; Remo Antonio Ranalletta; Mauro Pepi; Anna Garlaschè; Sarah Ghulam Ali; Laura Fusini; Valentina Mantegazza; Manuela Muratori; Riccardo Maragna; Gloria Tamborini
Journal:  J Clin Med       Date:  2022-08-03       Impact factor: 4.964

6.  Right ventricular functional assessment by three-dimensional transesophageal echocardiography is useful for withdrawal from a right ventricular assist device: a case report.

Authors:  Hiroki Taenaka; Tatsuyuki Imada; Ryuichiro Abe; Akinori Uchiyama; Yuji Fujino
Journal:  JA Clin Rep       Date:  2017-08-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.